User guide

4. Programming
496929 Page 23
78 Level D Entry Time
78YnY
1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
79 Level D Exit Time
79YnY
1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
81 Output 1 Type, one of
81YnY
Where n is one of the following:
00 Bell (default full/part set sys.)
01 EE follow
02 Armed lamp
03 Set latch
04 Shock sensor reset
05 Walk test
06 Ready lamp
07 24 hour alarm
08 Strobe
09 Smoke sensor reset
10 French Siren Test
11 Strobe Set
12 Pulse Set o/p 1
13 Pulse Unset o/p 1
26 Pulsed Set o/p 1
27 Pulsed Set o/p 2
28 Pulsed Set o/p 3
29 Pulsed Set o/p 4
30 Pulsed Unset o/p 1
31 Pulsed Unset o/p 2
32 Pulsed Unset o/p 3
33 Pulsed Unset o/p 4
82 Output 2 Type, one of
82YnY
See Command 81 for a list of options.
Default for Command 82 is 08 Strobe.
83 Output 3 Type, one of
83YnY
See Command 81 for a list of options.
Default for Command 83 is 03 Set
latch.
85 Burg Comms Rearm
85YnY
0 Latch Y
1 Rearm
86 Dual Ply Entry
86YnY
0 Off Y
1 On (not recommended in U.K.)
87 Dual Key Alarm
87YnY
0 Off Y
1 On
90 Event Log*
90YnY
0 Print log
1 View earlier events
3 View later events
X Cancel viewing
Y Toggles time/date display
91 Test Output 1 See “5. Testing”
91Y
Output 1 operates, press X or Y to end
test.
92 Test Output 2 See “5. Testing”
92Y
Output 2 operates, press X or Y to end
test.
93 Test Output 3 See “5. Testing”
93Y
Output 3 operates, press X or Y to end
test.
94 Test Internal Sounder (Single
System Only) See “5. Testing”
94Y
Internal sounders operate, press X or
Y to end test.
95 Test Kpd Sounder See “5. Testing
95Y
Keypad sounders operate, press X or
Y to end test.
97 Engineer Walk Test See “5. Testing”
97Y
Zn indication and chime operate when
cct open
Y (Clear) End walk test
98 Load Defaults
98Y1Y
99 Leave Programming
99YY
126 Language
126Y
nnY
nn = 0 = English(Y)
1 = Italian
2 = Espanol
3 = Portugu
4 = Nederl
5 = Francai
6 = Deutsch
7 = Norsk
8 = Svenska
9 = Dansk
151 Plug by Comms Output 1
151YnnY
nn 00 Not Used
01 Fire (default)
02 PA
03 Burglar
04 Open/Close
05 Alarm Abort
06 Technical Alarm
11 AC Fail
12 Tamper Alarm
13 Open
14 Close
15 Zone Omitted
16 Medical
17 Key-Box
18 Anti-Mask
19 Smoke Detector
30 Set o/p 1
31 Set o/p 2
32 Set o/p 3
33 Set o/p 4
34 Unset o/p 1
35 Unset o/p 2
36 Unset o/p 3
37 Unset o/p 4
152 Plug by Comms Output 2
152YnnY
Default 02 PA. See Command 151
153 Plug by Comms Output 3
153YnnY
Default 03 Burglar. See Command 151
154 Plug by Comms Output 4
154YnnY
Default 04 Open/Close. See Command 151
155 Plug by Comms Output 5
155YnnY
Default 15 Zone Omitted. See Command 151
156 Plug by Comms Output 6
156YnnY
Default 05 Alarm Abort. See Command 151