User guide

4. Programming
496929 Page 21
Command Key in:
0 Country PTT Defaults
0Y
nY
n = country, one of:
0 = UK (Y)
1 = Italy
2 = Spain
3 = Portugal
4 = Netherlands
5 = France
6 = Belgium
7 = Germany
8 = Switzerland
9 = Austria
X1 = Ireland
X2 = OEM 1
X3 = OEM 2
X4 = OEM 3
X5 = Norway
X6 = Denmark
X7 = Sweden
Note: If you carry out this Command
then the system will load all defaults for
the selected country.
01 - 08 Zone nn
nnYYab
nn = zone number 01 to 08
Note: For zones 1 to 8 key in “01” to
“08”.
a = Zone type, one of:
00 = NU (not used)
01 = PA (panic alarm)
02 = FR (fire zone)
03 = NA (normal alarm)
04 = 24 (24 hour zone)
05 = FE (final exit)
06 = ER (entry route)
07 = SA (Shock Analyser)
08 = TC (Technical)
09 = KB (Keybox)
10 = SD (Smoke detector)
11 = KM (Key switch momentary)
12 = KF (Key switch latched)
13 = AM (Anti mask)
14 = FB (forbikobler zone)
b = Zone attributes, any of:
X1 = C (chime)
X2 = S (soak test)
X3 = D (double knock)
X4 = O(Omit allowed)
B = b (armed in Level B)
C = c (armed in Level C)
D = d (armed in Level C)
X7 = Shock Analyser sensitivity (enter
a number in the range 1 (lowest) to 6
(maximum)
(default)
Z01=FEbcd
Z02=Erbcd
Z03-Z07=Nabcd
Z08=PA
Example: Zone 07 is a Normal Alarm, active
in Part Set B, Omit Allowed. Type in:
03 Normal Alarm
B Active in Part Set B
X4 Omit Allow
Y to store the value of the Command.
20 Engineer Code
20YnnnnY
nnnn = New engineer code 7890
21 Zone Configuration
21YnY
0 Close Circuit Y
1 Fully Supervised Loop
22 LS Chime Output
22YnY
Loudspeaker chime volume
0 Off ( Keypad only)
1 low, 9 = max 5
23 RedCare Reset
23YnY
0 Off Y
1 On
25 Internal Sounder
25YnY
0 LS Timed (Follows external bell) Y
1 Continuous
27 Exit Fault External Sounder
27YnY
0 Internal Y
1 Local
28 Status Display
28YnY
0 Panel status visible all the time Y
1 Panel status hidden 180s after setting
2 Display for 30 s on valid access code entry
29 Entry Alarm Delay Time
29YnY
0 Delay off Y
1 Delay on
30 PA Response
30YnY
0 Audible Y
1 Silent
31 Zone Tamper Reset
31YnY
0 Engineer reset off
1 Engineer reset on
33 System Reset
33YnY
0 Eng reset off Y
1 Eng reset on
34 PA Reset
34YnY
0 PA cust reset Y
1 PA eng reset
35 First Circuit Lockout
35YnY
0 Lock out on Y
1 Re-arm
36 Alarm Abort
36YnY
0 Abort off Y
1 Abort on
37 Day Tamper Comms
37YnY
0 Day Tamper off Y
1 Day Tamper on
38 System Tamper Reset
38YnY
0 Customer Reset
1 Engineer Reset Y
39 Level A Exit Mode
39YnY
0 Timed Y
1 Terminated
2 Final door
3 Lock Set
40 System Auto Re-Arm
40YnY
0 Rearm Never Y
1 Rearm 1
2 Rearm 2
3 Rearm 3
4 Rearm Always