User guide

3. Installation
496929 Page 15
To program the outputs use programming command 81 for OP1, command 82
for OP2 and command 83 for OP3 (see "4. Programming"). Figure 11 shows
some example applications for OP3
Shock Sensor Reset
Use Command 83 4
VIPER
+ve
0V
Bell Follow Buzzer/Relay
Use Command 83 0
Relay energises/buzzer sounds
when bell activates.
BUZZER/RELAY
PIR Set Latch/Walk Test
For:
Set Latch use Command 83 3
Walk Test use Command 83 5
PIR
OP3
OP2
OP1
12V
0V
TR
+
LS
12V AUX
0V
12V AUX
0V
OP3
OP2
OP1
12V
0V
TR
+
LS
12V AUX
0V
12V AUX
0V
OP3
OP2
OP1
12V
0V
TR
+
LS
12V AUX
0V
12V AUX
0V
Figure 11. Wiring Examples for Programmable Output OP3
Wiring Keyswitches
To allow a user to set and unset the system using a keyswitch, connect a
fixed position or spring loaded (momentary) key switch to a zone input. Note
that a key switch cannot reset the system. When programming the control unit
select zone type (KM) for momentary or (KF) for fixed position keyswitches.
Figure 12 shows the connections for a keyswitch.
Fixed Keyswitch (KF)
Keyswitch CC FSL System
OFF Closed 2k2 Unset
ON Open 6k9 Set
Momentary Keyswitch (KM)
Keyswitch CC FSL System
Operate Close-Open-
Close
2k2-6k9-2k2 Unset
Operate Close-Open-
Close
2k2-6k9-2k2 Set
Figure 12. Connecting a Keyswitch