Operator`s manual
11 
Control Panel Connection Table 
The table below shows connection details for various alarm control panels: 
Trigger Inputs  
Control Panel 
1 
 Fire 
2 
 PA 
3 
Intruder 
Trigger 
Polarity 
12V 
0V 
ADE Accenta 6  N/A  N/A  B  -ve  13V+  13V- 
ADE Concept 6  N/A  N/A  B  -ve  13V+  13V- 
ADE Optima 6  N/A  N/A  B  -ve  13V+  13V- 
ADE 
Optima XM 
N/A N/A  B  -ve 13V+ 13V- 
C&K 800L N/A N/A S- -ve Aux + Aux - 
CQR Premier 9  FA*  PA  IA  +ve  Aux 
12V 
Aux 
0V 
DA Abacus 6  N/A  N/A  Bell  -ve  +12V  -0V 
DA Abacus 8  N/A  N/A  Bell  -ve  +12V  -0V 
Gardtec 500 
Series 
N/A N/A Bell-  -ve  12V 0V 
Gardtec 800 
Series 
D1* PA 12Hr  -ve 12V 0V 
Menvier 
TS400/410 
Cct 4  Cct5  ALM  -ve  Aux +  Aux - 
Menvier TS 
Range 
Comm. 
1 
Comm. 
2 
Comm. 3  -ve  Aux +  Aux - 
Pyronix Octagon  N/A  PA  ALM  -ve  Aux +  Aux - 
Pyronix 
Conqueror 
N/A  N/A  BA  -ve  Aux +  Aux - 
Scantronic 9448  N/A  COM 2  COM 3  -ve  12V  0V 
Scantronic 9X5X 
Series 
Pin 1  Pin 2  Pin 3  -ve  Pin 9  Pin 10 
Texecom Veritas 
8/R8/ 
N/A  N/A  B  -ve  Aux +  Aux - 
Texecom Veritas 
R8 Plus 
Com1  Com2  Com3  -ve  Aux +  Aux - 
Texecom Veritas 
Excel 
Com1  Com2  Com3  -ve  Aux +  Aux - 
Texecom Premier 
48/88/168 
Digi1*  Digi2*  Digi3*  -ve  Aux +  Aux - 
*Control panel output may require programming to the correct 
function. 