6" Incandescent
91
DIMENSIONS
DESCRIPTION
EI700
6" Aperture, IC,
New Construction,
120V Line Voltage
Specifications
• Thermally protected IC
housing
• Housing may be
covered with insulation
• For use with 120V
incandescent lamps
The EI700 housing is designed
for use in insulated ceilings
where the housing will be
in direct contact with insulation.
EI700 may be converted into
AIR-TITE installation when used
with AIR-TITE trims. Look for the
AIR-TITE trim logo in this section.
Housing
• Aluminum construction for
greater heat dissipation.
• Rigid socket plate adjusts and
locks without tools for various
lamp sizes
Plaster Frame
• Housing adjusts in plaster
frame to accommodate up to
1-3/4” thick ceilings.
• Regressed locking screw for
securing hanger bars.
• Cutouts for easily crimping
hanger bars in position.
Junction Box
• Positioned to accommodate
straight conduit runs.
• Seven conduit knockouts are
uniform 1/2” size with true
pryout slots.
• Four pryouts with integral
strain relief simplify “NM”
non-metallic sheathed cable
installation.
• Three quick connect wire
connectors included.
ALL-NAIL™ Bar Hangers
Bar Hanger features include:
• Pre-installed nail.
• Mini leveling foot aligns the
housing to the bottom of the
joist.
• Housing can be positioned at
any point within 24” joist spans
• Score lines allow tool-free
shortening for narrow joist
spacing.
• Bar hangers may be
repositioned 90° on plaster
frame
• Integral T-bar clip snaps onto
T-bars – no additional clips are
required
Socket
Porcelain E26 socket with nickel
plated brass screw shell, snaps
into trim for consistent lamp
positioning.
Thermal Protector
Self resetting thermal protector
deactivates fixture if overheating
occurs due to improper lamping
or misapplied insulation.
Labels
• UL/cUL Listed 1598 Luminaire
• UL/cUL Listed for Damp Location
• UL/cUL Listed for Feed Through
• UL/cUL Listed for Wet Location,
covered ceiling
• UL/cUL Listed for Direct Contact
with Insulation and combustible
material
• IP Rated (Improper Lamp)
Note: Some units may have
different features.
Visit www.cooperlighting.com for more information on the complete ALL-PRO Stock and
Specification offering. Product availability subject to change without notice.
DIMENSIONS
DESCRIPTION
EI700R
6" Aperture, IC, Remodel,
120V Line Voltage
Specifications
• Thermally protected IC
housing
• Housing may be
covered with insulation
• For use with 120V
incandescent lamps
• For installation from
below the ceiling
The All-Pro EI700R remodel
housing is designed for existing
ceiling installations where the
housing will be in direct contact
with insulation. EI700R may be
converted into AIR-TITE
installation when used with
AIR-TITE trims. Look for the
AIR-TITE trim logo in this section.
Housing
• Aluminum construction for
greater heat dissipation.
• Rigid socket plate adjusts and
locks without tools for various
lamp sizes.
Remodel Clips
Four remodel clips secure
housing and accommodate
1/2" and 5/8" ceiling thickness.
Junction Box
• Seven conduit knockouts are
uniform 1/2" size with true
pryout slots.
• Four pryouts with integral
strain relief simplify “NM”
non-metallic sheathed cable
installation.
• Three quick connect wire
connectors included.
Socket
Porcelain E26 socket with nickel
plated brass screw shell, snaps
into trim for consistent lamp
positioning.
Thermal Protector
Self resetting thermal protector
deactivates fixture if overheating
occurs due to improper lamping
or misapplied insulation.
Labels
• UL/cUL Listed 1598 Luminaire
• UL/cUL Listed for Damp Location
• UL/cUL Listed for Feed Through
• UL/cUL Listed for Wet Location,
covered ceiling
• UL/cUL Listed for Direct Contact
with Insulation and combustible
material
7"
[178mm]
1/2"
[13mm]
6-1/4"
[159mm]
6-7/8"
[175mm]
13-1/4"
[337mm]
6-1/2"
[165mm]
1/2"
[13mm]
7"
[178mm]
10-1/2"
[267mm]
7-1/2"
[191mm]
Ceiling opening to match template supplied