Specifications
RLD6 Series
HALO
ORDERING INFORMATION
SAMPLE NUMBER: RLD6069301EWH
A complete luminaire consists of a housing, and LED module, order separately.
Models Lumens CRI / CCT Driver Finish Accessories
RLD6 = 6”Deep Baffle retrofit
LED module
06=600 lumen
(nominal)
930=90 CRI minimum,
3000K CCT
1E= 120V 50/60Hz leading
or trailing edge phase cut
1% dimming
WH= matte white trim,
white baffle and black
baffle included
Housings
Halo LED 6-inch
H750ICAT= 6” LED, Insulated Ceiling, Air-Tite, New Construction Housing
H750RICAT= 6” LED, Insulated Ceiling, Air-Tite, Remodel Housing
H750T= 6” LED, Non-IC, Air-Tite, New Construction Housing
H750TCP= 6” LED, Non-IC, New Construction/Remodel Chicago Plenum Housing
H2750ICAT= 6” LED, Shallow, Insulated Ceiling, Air-Tite, New Construction (use with 691X, 694X, 696X trims only)
H2750RICAT= 6” LED, Shallow, Insulated Ceiling, Air-Tite, Remodel (use with 691X, 694X, 696X trims only)
E750ICAT= 6” LED, Insulated Ceiling, Air-Tite, New Construction Housing
E750RICAT= 6” LED, Insulated Ceiling, Air-Tite, Remodel Housing
Halo LED retrofit
ML7E26RFK= 6” Retrofit Enclosure, Non-IC, E26 Screw base Interface
ML7BXRFK= 6” Retrofit Enclosure, Non-IC, BX Whip
Halo Shallow Housings 6-inch
H27ICAT= 6” Shallow, Insulated Ceiling, Air-Tite New Construction
H27RICAT= 6” Shallow, Insulated Ceiling, Air-Tite Remodel Housing
H27T= 6” Shallow, Non-IC, New Construction Housing
H27RT= 6” Shallow, Non-IC, Remodel Housing
E27ICAT= 6” Shallow, Insulated Ceiling, Air-Tite New Construction
E27RICAT= 6” Shallow, Insulated Ceiling, Air-Tite Remodel Housing
E27TAT= 6” Shallow, Non-IC, New Construction Housing
E27RTAT= 6” Shallow, Non-IC, Remodel Housing
Halo Standard Housings 6-inch
H7ICAT= 6” Insulated Ceiling, Air-Tite New Construction Housing
H7RICAT= 6” Insulated Ceiling, Air-Tite Remodel Housing
H7ICT= 6” Insulated Ceiling, New Construction Housing
H7RICT= 6” Insulated Ceiling, Remodel Housing
H7ICATNB= 6” Insulated Ceiling, Air-Tite New Construction Housing, No Socket Bracket
H7ICTNB= 6” Insulated Ceiling, New Construction Housing, No Socket Bracket
H7T= 6” Non-IC, New Construction Housing
H7RT= 6” Non-IC, Remodel Housing
H7TNB= 6” Non-IC, New Construction Housing, No Socket Bracket
H7TCP= 6” Non-IC, Chicago Plenum, New Construction/Remodel Housing
H7UICAT= 6” Insulated Ceiling, Universal, Air-Tite, New Construction Housing
E7ICAT= 6” Insulated Ceiling, Air-Tite New Construction Housing
E7RICAT= 6” Insulated Ceiling, Air-Tite Remodel Housing
E7ICATNB= 6” Insulated Ceiling, Air-Tite New Construction Housing, No Socket Bracket
E7TAT= 6” Non-IC, New Construction Housing
E7RTAT= 6” Non-IC, Remodel Housing
E7TATNB= 6” Non-IC, New Construction Housing, No Socket Bracket
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Photometric Data Product Specifications
RLD6069301EWH
Luminaire lumens 668
Input watts 8.5
LER (LPW) 78.6
Spacing
Criteria
0-180 1.08
90-270 1.08
Diagonal 0.98
Beam angle (degrees) 66.1
Field angle (degrees) 108.8
Zonal lumen Lumens % Lumens
0-30
372 55.7
0-40 507
75.9
0-60 621
92.9
0-90 668
100
* Tested in accordance with IES LM63. Field results may vary.
Lumens 668
Watts 8.5
Lumens Per Watt
(Efficacy) 78.6
Color Accuracy
(CRI) 91
PRODUCT
SPECIFICATIONS
2700K 3000K 4500K 6500K
Light Color (CCT) 3000K
Correlated Color Temperature (CCT)
warm white soft white bright white
Performance metrics are measured using white baffle.
Color Metric Summary
TM-30-15
R
f = 91
R
g = 98.8
CRI/CIE
R
a = 92.8
R
9 = 67.2
55°
CCT - Range of 2700K- 5000K