Command format *15G1A<CR>
Response format 15G1A15<CR>
3. Write “VLT” as units of measure into the EEPROM of the meter in the point-to-point mode:
Command format *W1F564C54<CR>
Response format W1F<CR>
where 56, 4C, 54 are the three HEX ASCII values for V, L, and T respectively.
4. Read alarm status character from the meter number 15 HEX:
Command format *15U01<CR>
Response format 15U01@<CR>
where “@” is the alarm status character, decoded using Table 8.5 or 8.6.
5. Enable setpoints number 3 and 4 in point-to-point mode:
Command format *E01<CR>
Response format E01<CR>
6. Hold display value on meter number 15 HEX:
Command format *15D04<CR>
Response format 15D04<CR>
7. Cold reset (reset 1) in point-to-point mode:
Command format *Z04<CR>
Response format Z04<CR>
8. Publish measurement string from the meter in point-to-point mode:
Command format *V01<CR>
Response format V01 567.891 567.880 712.345 110.765<CR>
9. Publish current reading value from the meter number 15 HEX in multipoint mode:
Command format *15X01<CR>
Response format X01 567.891<CR>
10. Read block of data from EEPROM in point-to-point mode:
Command format *R42<CR>
Response format R42271100010001EO3E003F<CR>
11. Display “HELLO” onto the meter number 15 HEX in multipoint mode:
Command format *15Y01HELLO<CR>
Response format 15Y01<CR>
8.10 Examples: Rate Meter/Totalizers/Batch
The following are examples of the different commands and their proper responses from rate meter/totalizers,
batch. For the following examples assume that:
a) echo mode
CF 125 INFINITY SC GUIDE 28 M1519/N/0605
b) “*” as the recognition character of the meter