Instruction Manual
0.001% of span/volt power supply rejection
EXTERNAL FUSE
REQUIRED:
115 Vac IEC 127-2/III,125 mA,250V (Time-Leg) or UL Slow Blow, 125mA, 250V
230 Vac IEC 127-2/III,63 mA,250V (Time-Leg) or UL Slow Blow, 63mA, 250V
ENVIRONMENTAL
OPERATING TEMP RANGE: 0 to 50 degrees C (32 to 140°F)
STORAGE TEMP RANGE: –40 to 85 degrees C (–40 to 202°F)
HUMIDITY: up to 95% non-condensing at 40°C (104°F)
FRONT PANEL: NEMA-4 rated
MECHANICAL
DIMENSIONS (H x W x D): 1.89 x 3.78 x 5.86 (48mm x 96mm x 145mm)(48 x 96 x 145mm)
PANEL CUTOUT (H X W): 1/8 din 1.772 X 3.622in 45 x 92mm)
WEIGHT: 1.316 pounds (600 g)
MATERIAL: 94V-0 UL-rated Polycarbonate
Figure 18-1. Dimensions for Meter Housing.
FLASHING MESSAGES
DURING PROGRAMMING (configuration mode)
NUMERICAL OVERFLOW: “999999”
OFFSET OVERFLOW: “ERR 01”
SETPOINT OVERFLOW: “ERR 02”
NOT STORED IN EEPROM: “NOSTOR”
VALUE PUT IN EEPROM: “STORED”
DURING MEASUREMENT (RUN MODE)
INPUT TOO LARGE, POSITIVE: “+ OVLD”
INPUT TOO LARGE, NEGATIVE: “– OVLD”
INPUT OUT OF RANGE, POSITIVE: “+ OPEN”
INPUT OUT OF RANGE, NEGATIVE: “– OPEN”
EXCESS INPUT SCALE/OFFSET: “I OVSC”
EXCESS DISPLAY SCALE/OFFSET: “R OVSC”
COUNT-BY DISPLAY OVERFLOW: “999999”
CF 67 72 M1291/N/0403 11279ML-02 Rev. A