Owner manual
DFI INFINITY CS (V- M3598/N/0906) 30 CF 70
ENVIRONMENT
Operating Temperature: 0° to 50°C (32° to 122°F)
Storage Temperature: -40° to 85°C (-40° to 185° F)
Relative humidity: 90% at 40°C (non-condensing)
MECHANICAL
Panel cutout: 1/8” DIN 3.62 x 1.78” (45 x 92mm)
Weight: 1.27 lb (575 g)
Case material: Polycarbonate, 94 V-O UL rated
Protection: NEMA-4/Type 4 Front Bezel
Table 8-1 Color Chart for DC Power
COLOR HIGH BRIGHTNESS MEDIUM & LOW BRIGHTNESS
RED
Sensor Excitation:
24 V @ 25 mA,
12 V, 10 V, 5 V @ 35 mA Max
Analog Output:
Non-Isolated option only
GREEN
AMBER
Warning:
• Do not use Internal Excitation.
Use External Excitation.
• Do not use Isolated Analog Output.
Use Non-Isolated Analog Output.
Any combination of Sensor
Excitation and Analog Output
24 V @ 25 mA,
12 V @ 35 mA Max
10 V @ 35 mA Max
5 V @ 35 mA Max
Analog Output:
Non-Isolated options or
Isolated Analog option
HIGH/LOW Brightness and AMBER are only available on Version “B” meters. Standard display meters are
MEDIUM Brightness.
Figure 8-1 Meter Dimensions/Panel Cutout