Instruction Manual

CF 146 10 V- Rev. 1.0 - 003R-620-100
(L1, L2, L3, L4, L5) <ITM> to return to CLR.LIN.
DIR.ZER
Direct Zero Calibration
(Current weight displays)
<OK> key to start. Current weight displays.
<OK> to enter direct zero setting (in mV/V). <SEL> changes position, <EDT>
changes digit.
<OK> key to store new zero calibration.
<ITM> to exit or <OK> to repeat operation.
DIR.SPN
Direct Span Calibration
(Current weight displays)
<OK> key to start. Current weight displays.
<OK> to enter direct span setting (in mV/V). <SEL> changes position, <EDT>
changes digit.
<OK> key to store new span calibration.
<ITM> to exit or <OK> to repeat operation.
FAC.CAL
Factory Calibration
Cont. N (No)
Cont. Y (Yes)
Cont. N
Warning: Choosing Cont. Y will restore default factory calibration in BUILD and
CAL menus.
Accept
SAFE.PC Safe Setup Passcode (000000 no passcode). Set up to 6 digit passcode.
<SEL> changes position, <EDT> changes digit.
Activated only when FULL.PC is also set.
Accept
FULL.PC Full Setup Passcode (000000 no passcode). Set up to 6 digit passcode.
<SEL> changes position, <EDT> changes digit.
Accept
KEY.LOC Front Panel Key Locking
P12345
(P for Power key. Other keys
numbered from the left, ie.
Zero=1.)
P12345
Character indicates key is unlocked.
() Dash indicates key is locked.
<SEL> changes position, <EDT> changes digit.
Accept
KEY.FN <FUNCTION> Key
Setting
NONE, TEST, COUNT, UNITS, HOLD, PEAK.H, LIVE.WT, SHOW.T Accept
AUT.OFF Auto Power Off /
Battery Operation
NEVER, 1, 5, 10 (time in minutes)
Default = Never powers off automatically
(Battery: powers down after 30 minutes)
Accept
B.LIGHT Backlight Operation ON, OFF
(Automatically turns indicator off after 10 seconds of inactivity)
Accept
SPEC
REM.FN Remote Function NONE, KEY1 to KEY5, BLANK
(Activated only when SERIAL:TYPE is set to KEY)
Accept
TYPE Serial Output Type NET, AUTO.1, AUTO.2, PRINT, MASTER, KEY Accept
BAUD Serial Baud Rate 2400, 4800, 9600 Accept
BITS Serial Format Options
Position 1: Parity
Position 2: Data Bits
Position 3: Stop Bits
Position 4: DTR Handshake
N 8 1 - (Default Serial Format Options)
<SEL> changes position, <EDT> changes digit.
Parity: N None, O Odd, E Even
Data Bits: 7 or 8 data bits
Stop Bits: 1 or 2 stop bits
DTR: (-) DTR disabled or d DTR enabled
Accept
ADDRES Instrument Address 01 to 31
<SEL> changes position, <EDT> changes digit.
Accept
SERIAL
RST.CON
Reset Printed
Consecutive Numbers to 1
Cont. N (No)
Cont. Y (Yes)
Cont. N
<ITM> to choose Cont. Y (Yes) or Cont. N (No)
Accept
SET.PTS SRC Weight Source OFF, GROSS, DISP (Displayed) Accept