User Manual
Setting ID Codes
Current Control Module Calibration
Permits the user to adjust minimum and maximum currents
1. Release the
[EStop]
on the
T150
.
2. Turn the
T150 ON
by toggling the
[SW5]
switch to the
UP
position.
3. While holding the
[SW5]
switch in the
UP
position, press and release the
[EStop]
switch. This enables the
“Download Password” mode.
4. Release the
[SW5]
switch. The
ACTIVE
LED will flash once per second.
5. Toggle the switches in sequence:
[SW3]
,
[SW1]
,
[SW4]
and then
[SW4]
to the
DOWN
position to enter the
password code (3144), followed by toggling the
[SW5]
switch to the
UP
position. The
ACTIVE
and
LOW BATT.
LED’s will flash alternately once per second. This confirms the
T150
is sending “Calibration Data” to the
R150
.
6. Select and hold one of the “Proportional Functions” (i.e.
[SW4]
or
[ROT CW]
).
7. With the trigger
OFF
(fully released), the “MIN” level is set. The “MIN” level may be increased by toggling the
[SW5]
switch up or decreased by toggling the
[SW5]
switch down.
8. With the trigger
ON
(fully engaged), the “MAX” level is set. The “MAX” level may be increased by toggling the
[SW5]
switch up or decreased by toggling the
[SW5]
switch down.
9. To reset the “MIN” and “MAX” settings to the factory default, hold the
[SW5]
switch in either the
UP
or
DOWN
position for 5 seconds.
10. To exit, press the
[EStop]
switch.
Required when replacing either the Transmitter or Receiver
The Transmitter has its
ID Code
factory programmed. Its matching receiver needs to have this same code
programmed into it. To do this, the Receiver needs to have its cover removed – refer to Figure 2. Follow the
procedure below to program the Receiver
ID Code
to match its corresponding Transmitter.
1. Release the
[EStop]
switch on the
T150
.
2. Turn the
T150
on by toggling the
[SW5]
switch to the
UP
position.
3. While holding the
[SW5]
switch in the
UP
position, press and release the
[EStop]
switch. This enables the
“Download Password” mode.
4. Release the
[SW5]
switch. The
ACTIVE
LED will flash once per second.
5. Toggle the switches in sequence:
[SW3]
,
[SW1]
,
[SW4]
and then
[SW2]
to the
UP
position to enter the
password code (3142), followed by toggling the
[SW5]
switch to the
UP
position. Both the
ACTIVE
and
LOW
BATT.
LED’s will flash twice per second. This confirms the unit is in the “Ready to Download” state.
6. Press and hold the
[SETUP]
button on the
R150
for 5 seconds. The
STATUS
LED on the
R150
will flash once
per second while depressed and then begin flashing rapidly indicating that the
R150
is ready to receive
“Configuration Data” from the
T150.
Continue holding the
[SETUP]
button after the
STATUS
LED begins
flashing rapidly.
7. Momentarily toggle the
[SW5]
switch to the
UP
position; this enables the
T150
to send “Configuration Data” to
the
R150
.
Release
[SW5]
and release the
[SETUP]
button.
8. Press the
[EStop]
switch to power down the
T150
, and restart the
T150
– refer to
STEP 2.