User's Manual
11
DM-R2160-0007A (Rev 1)
www.omnexcontrols.com
call toll free: 1-800-663-8806
Tether connection detected
The Active light remain on momentarily when a function is activated (i.e. a switch or
paddle is triggered). This is normal operation.
Normal Operation
The transmitter is in Download Mode.
Normal Operation
The Active light will flash 2 times per second, indicating that the transmitter is sending
signals to the receiver.
Stuck switch detected. Ensure that all switches are in a centered position. The trans-
mitter will not power up when a function is ON.
STOP
STOP
STOP
STOP
STOP
Light Legend
Solid
Slow
Flash
Fast
Flash
Red
Light
Green
Light
Alternating Red
& Yellow Light
Yellow
Light
Diagnostics—T2400 Transmitter
Status
Module 1
Module 2
Module 3
Module 4
Module 5
Module 6
Module 7
Status Indicator
Module is operating properly
Low battery condition detected
There is a fault with the module Fuse blown
Communication to the module is active
STATUS
STATUS
STATUS
STATUS
STATUS
Module is installed and operating properly
There is a short to supply
There is a short to ground / over current No Module installed
Module 1-7 Indicators
MODULE
MODULE
MODULE
MODULE
Indicator lights for the D180 Expansion Module
Diagnostics - D180 Expansion Module