User's Manual

10
DM-R2160-0007A (Rev 1)
www.omnexcontrols.com
call toll free: 1-800-663-8806
Light Legend
Solid
Slow
Flash
Fast
Flash
Red
Light
Green
Light
Alternating Red
& Yellow Light
Yellow
Light
The transmitter’s joysticks control the receiver’s proportional outputs. A proportional output can be activated when a joy-
stick is moved; it will become active at an increasingly high level as the joystick is pushed/pulled. The min. and max. lev-
els of the proportional output can be calibrated by following these steps.
Refer to the Light Legend below for diagram details.
NOTE: Calibration settings can be reset to factory default in steps 3 & 4 by holding the [Power] switch UP or DOWN for 5 seconds
.
A. Refer to steps in “Power the
Transmitter”
1. Power T2400, Power R2160
A. Hold [Calibrate] switch
DOWN for 5 seconds until the
(Battery) LED fast flashes
RED
B. Release [Calibrate] switch
2. Setup T2400 into Calibration Mode
3. Set Minimum Level
A. Slightly push the paddle (function) in
the direction you wish to calibrate
until the (Active) LED comes on
B. Hold paddle and Press [Calibrate]
switch UP to increase minimum
level or DOWN to decrease it
4. Set Maximum Level
A. Fully push the paddle (function) in
the direction you wish to calibrate
until the (E-Stop) LED comes on.
B. Hold paddle and Press [Calibrate]
switch UP to increase maximum
level or DOWN to decrease it
5. Power Off
A. Unlatch the POWER [ON] switch.
Note:
Repeat steps 3 and 4 for each paddle (function) that needs to be calibrated.