Cut Sheet

www.eaton.com
www.eaton.com/arrowhart
F-29
EATON 2016 Arrow Hart Buyers Guide
SECTION
F
Testing & code compliance: Listed to UL1691, Listed to CSA C22.2, No. 1691-12, CSA certified to C22.2, No. 182.3 LR 13963
Material characteristics: Insulator: TPE, Environmental: NEMA 3R, Temperature rating: Operating ambient: -40º C to 105º C
Compliances, specifications and availability are subject to change without notice.
Crimp non-vulcanized male plugs
Cable size Color Complete part no. Contact only part no. Insulator only part no.
3/0-4/0
BK E1016-8030 A200038-6B A200074-13
RD E1016-8032 A200038-6B A200074-15
GR E1016-8034 A200038-6B A200074-17
WH E1016-8035 A200038-6B A200074-18
BU E1016-7708 A200038-6B A200074-37
BRN E1016-7709 A200038-6B A200074-46
ORG E1016-8033 A200038-6B A200074-16
YEL E1016-8031 A200038-6B A200074-14
Crimp non-vulcanized female plugs
Cable size Color Complete part no. Contact only part no. Insulator only part no.
3/0-4/0
BK E1016-8080 A200035-14B A200075-13
RD E1016-8082 A200035-14B A200075-15
GR E1016-8084 A200035-14B A200075-17
WH E1016-8085 A200035-14B A200075-18
BU E1016-7724 A200035-14B A200075-37
BRN E1016-7725 A200035-14B A200075-51
ORG E1016-8083 A200035-14B A200075-16
YEL E1016-8081 A200035-14B A200075-14
For E1016 elastomeric, non-vulcanized, crimp connection, see page F-51
To order single packaged products add a “K” suffix to the complete part number
J-series E1016, elastomeric, non-vulcanized, crimp connection
Features
Double cam principle provides a positive,
vibration-proof connection
Self-compensating for wear
No moving contact surfaces, eliminating arcing
or burning
Superior electromechanical connections
Locked contacts will withstand a pulling force
of 1,000 lbs.
1/3 of a turn assures a high pressure contact
approaching 600 lbs. per sq. in. providing
minimum resistance
Contacts carefully machined from a high conductivity
brass to a smooth sliding fit and easy locking action
Watertight elastomeric insulators molded from
colorfast material, color-coded for easy phase
identification
Recessed contacts protected by insulating jacket
that extends beyond contact ends for safety
Integrated strain relief system features a retaining
wire that prevents cable jacket pull-away and bare
conductor exposure
Plugs feature a high-strength, molded-in-place
locking ring to capture and secure the insulator
to the contact
E1016-8035
E1016-7724
Single pole connectors
Cam-Lok™ J-series E1016 plugs
Product description
Cable size 3/0 – 4/0
600V AC/DC, up to 315A continuous
NEMA 3R
Color information:
BK (Black), RD (Red), GR (Green), WH (White), BU (Blue), BRN (Brown), ORG (Orange), YEL (Yellow)
BK RD GR WH BU BRN ORG YEL
(Black) (Red) (Green) (White) (Blue) (Brown) (Orange) (Yellow)
Cam-Lok™ J-series E1016 plugs