User manual
www.cooperbussmann.com/wirelessresources
Cooper Bussmann 245U-E Wireless Ethernet Modem & Device Server User Manual
73Rev Version 2.19
Owner Owner name.
Contact Owner contact information (such as phone number and email address).
Description Description of the purpose of the unit.
Location Location of the 245U-E.
3.25 Configuration Examples
Setting a 245U-E to Factory Default Settings
1. Access the Configuration webpage on the 245U-E.
For details, see “3.2 Configuring the Unit for the First Time.”
2. Click the System Tools menu item.
3. Click Factory Default Configuration Reset and wait for the unit to reset.
While the module executes the reset sequence the OK LED will flash. The OK LED will turn green when the
reset sequence is complete.
Extending a Wired Network
Figure 75 Example Configuration 1
Access Point Configuration
1. Connect a straight-through Ethernet cable between the PC and the 245U-E.
2. Ensure that the configuration of the PC and 245U-E are setup to communicate on the same network.
3. Set DIP switch to SETUP mode.
4. Power up the unit and wait for the OK LED to stop flashing.
5. Adjust the PC network settings.
6. Set Configuration PC network card with the network setting of IP address 192.168.0.1, netmask 255.255.255.0.
7. Open the Configuration webpage within Internet Explorer at https://192.168.0.1XX/, where “XX” is the last two
digits of the module’s serial number.
8. When prompted for the password, enter default username “user” and password “user.”
9. Click Network and set the Operating Mode to “Access Point.”