User manual

86 www.cooperbussmann.com/wirelessresources
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual
Rev Version 1.0
System Warning Commands
CLI Commands Level Description Example
syslog mode
[client|server|both]
G Specified the log mode. switch>enable
switch#configure
switch(config)# syslog mode both
syslog ip
[IP address]
G Set system log server IP address. switch>enable
switch#configure
switch(config)# syslog ip
192.168.1.100
show syslog P
Show SYSLOG configuration and log
table.
switch>enable
switch#configure
switch#show syslog
no syslog G
Disable system log functon.
switch>enable
switch#configure
switch(config)#no syslog
event system-restart
syslog
G Set device restart event type. switch>enable
switch#configure
switch(config)#event system-restart
syslog
event authentication-
failure syslog
G Set Authentication failure event type. switch>enable
switch#configure
switch(config)#event authentication-
failure syslog
event syslog
[Link-UP|Link-Down|Both]
I Set port event for SYSLOG. switch>enable
switch#configure
switch(config)#interface fastethernet 3
switch(config-if)#event syslog both
show event P Show event selection. switch>enable
switch#show event
no event system-restart
syslog
G Disable device restart event type. switch>enable
switch#configure
switch(config)#no event system-
restart syslog
no event authentication-
failure syslog
G Disable Authentication failure event
type.
switch>enable
switch#configure
switch(config)#no event
authentication-failure syslog
no event syslog I Disable port event for system log. switch>enable
switch#configure
switch(config)#interface fastethernet 3
switch(config-if)#no event syslog
Traffic Prioritization Commands
CLI Commands Level Description Example
qos prioritytype
[port-based|cos-only|tos-
only|cos-first|tos-first]
G Setting of QoS priority type. switch>enable
switch#configure
switch(config)#qos prioritytype port-
base