35Rev Version 1.0
Current MIB Tables Lists the existing MIB views.
View Name Enter the name of the MIB view to be added (or removed).
Sub-OID Tree Enter the OID defining the root of the subtree to which the view will be included or
excluded.
Type Select whether the sub-OID tree should be included with or excluded from the named
view.
Add Adds the new MIB view.
Remove Removes the MIB view selected in the Current MIB Tables list.
6.4.7 System Alert
System Alert Relay Alarm
The Fault Relay Alarm function provides power failure and port link down/broken detection. To configure this
function, choose System-->System Alert-->Relay Alarm.
For the power failure settings, if the power input 1 and power input 2 are installed and the checkboxes for PWR1
and PWR 2 are selected, the fault LED on the front panel will turn on when a power failure occurs.
For the port link down/broken setting, if the checkbox for a port is selected the fault LED will turn on when that port
fails. See “3.5 Wiring the Fault Alarm Contact” for information on failure detection.
Figure 32 System Alert - Relay Alarm (Fault Relay Alarm)
Power Failure
Setting
Select the checkbox if you want the fault LED indicator (PWR 1, PWR 2) on the panel
to turn on when power fails.
Port Link Down/
Broken Setting
Select the port checkbox if you want the fault LED on the panel to turn on for that
port when the port link is down or broken.
Apply Click to apply the setting.
System Alert Event
If the Syslog Mode option is enabled on the Syslog Configuration page (see “6.4.5 Syslog”) you can use the System
Alert-Event page to select whether system restart, power status, and SNMP authentication failure events are sent to
the Syslog.
To display this page, choose System-->System Alert-->Event.