Cooper Bussmann Read and Retain for Future Reference 2080E-T Managed Ethernet Switch User Manual Version 1.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Interference Issues This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial or industrial installation.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual No part of this documentation or information supplied may be divulged to any third party without the express written consent of Cooper Bussmann/ELPRO Technologies. Products offered may contain software that is proprietary to Cooper Bussmann/ELPRO Technologies. The offer or supply of these products and services does not include or infer any transfer of ownership.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CONTENTS Chapter 1 - INTRODUCTION. . . . . . . . . . . . . . . . . . . 6 1.1 Module Identification. . . . . . . . . . . . . . . . . . . . . . 6 1.2 Mechanical Specifications. . . . . . . . . . . . . . . . . . 6 1.3 Order Information. . . . . . . . . . . . . . . . . . . . . . . . . 7 1.4 Hardware Features . . . . . . . . . . . . . . . . . . . . . . . 7 1.5 Software Features. . . . . . . . . . . . . . . . . . . . . . . . 8 1.6 Package Contents. . .
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.7.3 Factory Defaults. . . . . . . . . . . . . . . . . . . . . . 65 6.7.4 Firmware Upgrade . . . . . . . . . . . . . . . . . . . . 66 6.7.5 Export/Import . . . . . . . . . . . . . . . . . . . . . . . . 67 6.7.6 Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . 69 Ping . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 6.8 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . 69 Appendix A - RJ-45 PIN ASSIGNMENT . .
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Chapter 1 - INTRODUCTION The 2080E-T Managed Ethernet Switch is is an 8-Port 10/100 TX switch that provides a cost effective solution that meets the high reliability requirements demanded by industrial applications. 1.1 Module Identification The identification label is located on the bottom of the 2080E-T Switch. This label contains the model number, temperature range, power range, serial number, and all certifications.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 1.3 Order Information Item Product Code Description Data Sheet Ethernet Switch 2080E-T 8 Port 10/100TX Managed Ethernet Switch 10102 1.4 Hardware Features Feature Description Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX IEEE802.3x Flow Control and Back Pressure IEEE802.3ad Port Trunk with LACP IEEE802.1d Spanning Tree/ IEEE802.1w Rapid Spanning Tree IEEE802.1p Class of Service IEEE802.1Q VLAN Tag IEEE 802.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Feature Description Safety UL, cUL, CE/EN60950-1 UL Class 1 Division II for Group A, B, C and D Hazardous Location Stability Testing IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) 1.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Feature Description DHCP Provides DHCP client/ DHCP server/port and IP binding DNS Provides DNS client feature and supports primary and secondary DNS server SNTP Supports SNTP to synchronize system clock in Internet Firmware Update Supports TFTP/Web firmware update Configuration Upload/ Download Supports binary format configuration file for system quick installation Supports TFTP backup and restore ifAlias Each port allows importing 1
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Chapter 2 - HARDWARE DESCRIPTION This chapter describes hardware specifications, ports, cabling information, and wiring installation information for the 2080E-T. 2.1 Front Panel The front panel includes eight 10/100 TX RJ-45 ports, one RS-232 connector (RJ-45 type) for connecting to a console (terminal or PC), a pin-hole reset button, and diagnostic LEDs. LEDs Console Port 10/100 TX Ports (8) Figure 3 Front Panel of 2080E-T Switch 10 www.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 2.2 Top View The top panel of the 2080E-T Switch includes one terminal block connector. The terminal block has two DC power inputs and one fault alarm. Figure 4 Top Panel of 2080E-T Switch 2.3 LED Indicators The diagnostic LEDs are located on the front panel of the 2080E-T Switch, and provide real-time information about the system. The following table describes LED states.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 2.4 Pin-hole Reset Button Pressing the pin-hole reset button for more than five seconds will cause the 2080E-T to return to its factory default settings. 12 www.cooperbussmann.com/wirelessresources Rev Version 1.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Chapter 3 - HARDWARE INSTALLATION This chapter describes how to install the 2080E-T Managed Ethernet Switch. 3.1 Installation Steps 1. Unpack the 2080E-T Ethernet Switch. The DIN rail is screwed onto the switch by default. To wall mount the 2080E-T Switch, refer to “3.3 Wall Mount Plate Mounting.” 2. Hang the switch on the DIN rail track or wall. 3. Power on the switch. For information on wiring the power, see “3.4 Wiring the Power Inputs.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 1. Insert the top of the DIN rail into the track. 2. Press the DIN rail into the track. 3. Check that the DIN rail is firmly secured to the DIN rail track. To remove the industrial switch from the track, reverse the steps above. 3.3 Wall Mount Plate Mounting Follow these steps to mount the switch using a wall mount plate. 1. Loosen the screws to remove the DIN rail from the 2080E-T Switch. 2.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 3.4 Wiring the Power Inputs Use the following steps below to insert the power wire. 1. Insert the DC power wires into the contacts for power 1 and power 2, as shown below. Power 1 Power 2 2. Tighten the wire-clamp screws to prevent the wires from coming loose. Power 1 Power 2 NOTE The wire gauge for the terminal block should be within the range 12–24 AWG. Rev Version 1.0 www.cooperbussmann.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 3.5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector, as shown in Figure 6. Insert the wires into the fault alarm contacts. After the wires are inserted, the switch detects the fault status of the power failure or port link failure, and then forms an open circuit. Figure 7 shows an application example for wiring the fault alarm contacts.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Chapter 4 - NETWORK APPLICATIONS This chapter provides sample applications for the Cooper Bussmann/ELPRO Technologies Industrial Ethernet Switches. Figure 8 Sample Application 4.1 Pro-Ring2se Application Pro-Ring2se is a new ring mechanism for the Cooper Bussmann/ELPRO Technologies Industrial Ethernet Switches. As Figure 10 shows, Pro-Ring2se can be constructed using two ports of the same type in each 2080E-T. Refer to the section “6.5.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 10 Pro-Ring2se Connection Example 18 www.cooperbussmann.com/wirelessresources Rev Version 1.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Chapter 5 - CONSOLE-BASED MANAGEMENT The 2080E-T Managed Ethernet Switch supports a CLI command interface that can be accessed by connecting the switch to a terminal or a PC running a terminal emulator. This chapter describes how to connect and log onto the Console port (see Figure 3). Refer to “Appendix B - COMMAND SETS” for command descriptions and examples. 5.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual • Baud Rate: 9600 bps • Data Bits: 8 • Parity: none • Stop Bit: 1 • Flow control: none Figure 13 Communication Parameters 3. After setting the communication parameters, click OK. 4. At the blank screen, press Enter to display the login prompt. 5. At the login prompt, type the default user name “admin” and press Enter.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Chapter 6 - WEB-BASED MANAGEMENT The 2080E-T Switch has an embedded Web-based management utility that resides in flash memory on its CPU board. This utility offers advanced features that allow you to manage the switch from anywhere on the network through a standard browser such as Microsoft® Internet Explorer®. The utility supports Internet Explorer version 8.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.3 Web Page Overview The Web-based Management Utility uses a standard Web interface with the menu tree on the left. Click to expand a menu, and click to collapse a menu. You can also expand or collapse the entire menu tree by clicking Open All or Close All. Click a menu item go to the page. The Help button at the bottom of each page displays additional information about page contents. Figure 16 Home Page - Web-based Management Utility 6.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 17 Switch Information Page System Name System name of the switch. System Description Switch description. System Location Physical location of the switch. System Contact Name of contact person or organization. System OID SNMP OID of switch. Firmware Version Switch firmware version. Kernel Version Kernel software version. Device MAC Unique hardware address assigned by the manufacturer. System Time Current time on switch.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual System Name Assign the system name of the switch (the maximum length is 64 bytes). System Description Switch description. System Location Physical location of the switch (the maximum length is 64 bytes). System Contact Name of contact person or organization. System OID: SNMP OID of switch. Firmware Version Displays the switch’s firmware version. Kernel Version Displays the kernel software version.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.4.2 Time - SNTP To enable or disable the SNTP time function or set daylight savings time, choose System-->Time-->SNTP. SNTP (Simple Network Time Protocol) is a simplified version of NTP which is an Internet protocol used to synchronize the clocks of computers to a specified time reference. Because time typically advances, the time on various node stations will be different.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Daylight Saving Offset For non-US and European countries, specify the amount of time for day light savings. You can specify between 0 and 12 hours. Apply Click to apply the settings.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.4.3 Account - Admin Use the Admin page to change the login username and password for the Web-based Management utility to ensure access security. Choose System-->Account-->Admin to display this page. Figure 21 Admin Page User Name Type the new user name (the default is “admin”). New Password Type the new password. Confirm Password Re-type the new password. Apply Click to apply the settings. 6.4.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual IP Address Enter a static IP address to the switch from the subnet address range that the network is using. If the DHCP Client option is enabled, the switch is configured as a DHCP client. The network DHCP server will assign the IP address to the switch and the switch displays it in this column. The default IP address is 192.168.1.88. You can also choose an IP address manually when the DHCP Client option is disabled.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Syslog Log To display the current system event log (Figure 24), choose System-->Syslog-->Log. Click Reload or press F5 to refresh the page to view the most recent events. Figure 24 Log Page Reload Reloads the current log. Clear Clears the log contents. 6.4.6 SNMP SNMP Agent Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (for example, servers, workstations, routers, switches and hubs) on an IP network.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 25 SNMP Agent Configuration Agent Mode Select the SNMP version (V1/V2c or V3) that you want to use. And then click Apply to switch to the selected SNMP version mode. SNMP V1/V2c Community Allows you to define the new community string set and remove the unwanted community string. Community String Enter the name string. Privilege • Read Only—Enables requests accompanied by this community string to display MIB-object information.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual • DC power status trap • Topology change trap Figure 26 SNMP - Trap (Trap Manager) Server IP Enter the IP address of the trap manager. Community Enter the community string for the trap station. Trap Version Select the SNMP trap version type—v1 or v2c. Add Click to apply the settings. Remove To remove the community string, select the community string listed in the current manager’s field and click Remove.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual An item of management information may exist in more than one context. An SNMP entity potentially has access to many contexts. In other words, if an item of management information has been defined under a certain context by an SNMPv3 entity, any management application can access that information by providing that context name. Figure 27 SNMPv3 Context Tab Context Name Enter a name for the context table. Apply Click to apply the setting.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Use the Group tab to configure the SNMPv3 group table The group name created in this tab is associated with the user ID. Both the group name and the user ID are used as parameters to create entries in the access table that appears in the Access tab. Figure 29 SNMPv3 Group Tab Current Group Content List of existing groups (and their associated user IDs). To remove a group, select the group and click Remove.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Current Access Tables Lists the existing access table profiles. Context Prefix Enter the context prefix to be used to identify the context name. Group Name Enter the group name associated with this access profile. Security Level Select a security level for users of the access profile: • NoAuthNoPriv—User is not authenticated. Packets are not encrypted. • AuthNoPriv—User is authenticated. Packets are not encrypted.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Current MIB Tables Lists the existing MIB views. View Name Enter the name of the MIB view to be added (or removed). Sub-OID Tree Enter the OID defining the root of the subtree to which the view will be included or excluded. Type Select whether the sub-OID tree should be included with or excluded from the named view. Add Adds the new MIB view. Remove Removes the MIB view selected in the Current MIB Tables list. 6.4.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual NOTE If you also want the port event log to be sent to the Syslog server, be sure to set the triggers (link up, link down, and both) in the Port Alert page (see “Port Alert”). Figure 33 System Alert - Event System Restart When enabled, the system will issue an alert to the system log server when the device executes a cold start. It may take a minute after the cold start before the event appears in the system log server.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 34 DHCP Server Configuration DHCP Server Enable or disable the DHCP server function on the switch. When enabled, the switch will be the DHCP server on your local network. Start IP Address Enter the IP address that is the beginning of the dynamic IP address range. For example, if the dynamic IP address is between 192.168.1.100 and 192.168.1.200, the start IP address would be 192.168.1.100.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 36 IP Binding Apply Click to apply the setting. 6.5 Configure Menu 6.5.1 Port Port Configuration To configure the settings of each port to control the connection parameters, choose Configure-->Port-->Configuration. The status of each port is listed at the bottom of the page. Figure 37 Port Configuration 38 State Allows you to enable or disable the port. When the port is disabled, it will not receive or transmit packets.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Flow Control Flow control determines whether the receiving node sends feedback to the sending node. Three options are available: • Disable—Disables flow control capability. • Symmetric—Flow control is determined by auto-negotiation, and is only used when both linked ports have flow control enabled. • Asymmetric—Flow control is always active, regardless of whether the linked partner port is enabled.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 39 Port Statistics Port Port number. Type Displays the current speed of connection to the port. Link Current link status: • Up—Link is operational. • Down—Link is not operational. State State set on the Port Configuration page (see “6.5.1 Port”). When the state is disabled, the port will not transmit or receive packets. TX Good Packet Number of good packets transmitted via this port.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual To display this page, choose Configure-->Port-->Port Alert. Figure 40 Port Alert Port Event For the Port Event menus to become available, the “Client Only” option in Syslog Configuration must be enabled (see “6.4.5 Syslog”). There are four port event options: • Link Up—The system will only issue a log message when the link-up event occurs for the port.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 41 Rate Limit Egress Setting Allows you to set the egress rate limit (in kbps) for each port. The range is from 100 kbps to 102400 kbps (100 Mbps). Note that 1 Mbps is equal to 1024 kbps. Zero indicates no egress rate limit. Apply Click to apply the settings. Storm Control Use this page to set the ingress rate limit and select what kind of frames are to be filtered by the ingress rate limit.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Ingress Limit Frame Type Select the frame type to be filtered: • • • • All Broadcast/Multicast/Flooded Unicast Broadcast/Multicast Broadcast only Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast, and Broadcast only types are only for ingress frames. The egress rate only supports the “All” type. Ingress Set the ingress rate limit, in kbps. (One Mbps is equal to 1024 kbps.) The range is from 100 kbps to 102400 kbps (100 Mbps).
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Type Select the trunk group type for the port (Static or LACP). • Static—When Static is selected as the trunk group type for a port, the port belongs to the trunk group whose ID is selected in Group ID drop down menu for that port. Static trunk groups are only allowed to aggregate traffic in two to four ports. When ports belong to a static trunk, the traffic in the trunk group is distributed evenly among the ports belonging to the trunk group.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual RSTP Settings The Spanning Tree - RSTP Settings page provides the bridge and port configuration interface for RSTP. You can assign a higher or lower priority to each port. When RSTP is enabled, the port with the higher priority is in the forwarding state and other ports are blocked to make certain there is no loop in the LAN. To configure RSTP settings, choose Configure-->Spanning Tree-->RSTP Settings.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual P2P The rapid state transitions possible within RSTP depend on whether the port concerned can only be connected to a specific bridge (it is served by a point-to-point LAN segment), or can be connected to two or more bridges (it is served by a shared medium LAN segment). This function allows the P2P (point-to-point) status of the link to be manipulated administratively.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Root Port The port used to connect to the root switch. This port has the lowest root path cost. Root Path Cost Indicates how suitable this port is as a node for the Spanning Tree topology. A lower value indicates greater suitability. Max Age Time The number of seconds that this device waits before checking to see if it should change to a different state.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Control VLAN ID Because the Pro-Ring2se master switch generates BPDU packets every 10 ms to check the connection status, and the same BPDU packet is used by other switches to find a target switch, it is better to isolate the BPDU packets used for checking connection status from those used for other purposes. The best way to resolve this is to use VLAN for isolating the BPDU packets.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual NOTE There must be at least one switch that is enabled for IGMP query in your network. All other switches must enable IGMP snooping. Figure 48 IGMP Snooping IGMP Snooping Enable or disable the IGMP protocol. IGMP Query Mode Enable or disable the IGMP query function. The IGMP query information will be displayed in IGMP Snooping Table section.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 49 Static Filtering IP Address Assign a multicast group IP address in the range 224.0.0.0 to 239.255.255.255. Member Ports Select the port checkbox to include the port as a member in the specified multicast group IP address. Add Click to add the address to the multicast filtering list. Delete Click to remove a selected filter. 6.5.7 LLDP Link Layer Discovery Protocol (LLDP) is defined in the IEEE802.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual LLDP Interval Set the interval (in seconds) for advertising the switch information to other nodes. Sync Time Enables or disables switch clock synchronization using LLDP. Apply Click to apply the settings. LLDP Neighbors The LLDP Neighbors page displays information about the port neighbors discovered using the LLDP protocol. To display this page, choose Configure-->LLDP-->LLDP Neighbors. Figure 51 LLDP Neighbors 6.5.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual MAC Address Configuration Set the aging time (in seconds) for the MAC address table. Select the Auto Flush checkbox if you want the MAC address table to be erased if the port link fails. Security Enable or disable secure learning mode. When enabled, only static MAC addresses are learned; all other frames are dropped.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 802.1Q VLAN Mode—If you choose 802.1Q VLAN mode (Figure 54), you can see the link type, untagged VID, and tagged VID information of each port. Figure 54 VLAN Configuration - 802.1Q VLAN Operation Mode Select the VLAN operation mode, or disable VLAN. The following fields appear when you choose 802.1Q VLAN mode.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual • IQ Trunk Link—This link type only supports multiple tagged VIDs. The IQ trunk link is a segment that provides the link path for one or more VLAN‑aware devices (switches). A trunk port, connected to the trunk link, has an understanding of tagged frame, which is used for communication among VLANs across switches. Which frames of the specified VIDs will be forwarded depends on the values filled in the Tagged VID column field.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Port Based VLAN Mode—Port Based VLAN mode provides a simple way to create a VLAN. To create a new port based VLAN, first choose “Port Based” in the Operation Mode field (see Figure 55), and then click Add. The screen now looks like Figure 56. Simply name the VLAN, assign a VLAN ID, and select the ports to be included in the VLAN.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Operation Mode Select the VLAN operation mode or disable VLAN. The following fields appear when you choose Port Based VLAN mode. Group Name Assign a name to the VLAN. VLAN ID Assign an identifier to the VLAN. Add To add a port to the VLAN, click the port in the left port column and click Add. The port appears in the right column, indicating that it is in the VLAN.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual QoS Mode Select from the following modes, or select “Disable” to turn off QoS. • • • • • QoS Policy Port Based—The output priority is determined by the ingress port. COS Only—The output priority is determined by COS (Class of Service) only. TOS Only—The output priority is determined by TOS (Type of Service) only. COS First—The output priority is determined by COS and TOS, but COS first.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 60 COS Mapping to Queue COS Priority Each COS has four priority levels to choose from: High, Middle, Low, Lowest. COS Port Default Assign a default priority value to each port. A default priority is considered and determined by the ingress port when an ingress packet has no VLAN tag. Apply Click to apply the setting.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual DSCP priority The system provides 0–63 DSCP priority levels. Each level has four priority types: High, Middle, Low, and Lowest. When an IP packet is received, the system will check the DSCP level value in the packet and grant it the appropriate priority. For example, if you set DSCP level 25 as “High,” and system finds that the DSCP value of the received IP packet is 25, the packet will receive highest priority.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 63 IP Source Guard - Configuration IP Security Mode Enable or disable IP security. When security is enabled, the fields on this page become active. Enable Web Management When this checkbox is selected, any device whose IP address matches one of the 10 IP addresses in the Security IP1–IP10 table (see the next section) will be given permission to access this switch via HTTP service.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 64 IP Source Guard - Static Table Security IP 1–10 Enter the IP addresses that will be allowed to access and manage the switch through the HTTP/Telnet service. Apply Click to apply the settings. 6.6.2 802.1X/Radius The IEEE authentication specification 802.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 65 802.1X Radius - Configuration IEEE 802.1x Protocol Enable or disable 802.1x protocol. When enabled, the configuration parameters become available. Radius Server IP 62 Assign the RADIUS server IP address. Server Port Set the UDP destination port for authentication requests to the specified RADIUS server. Accounting Port Set the UDP destination port for accounting requests to the specified RADIUS server.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 802.1X/Radius Port Setting You can configure the 802.1x authentication state for each port. To configure the port settings, choose Security-->802.1x/Radius-->Port Settings. Figure 66 802.1X Radius - Port Setting Port Authorization Mode You can choose from the following authorization states: • Reject—The specified port is required to be held in the unauthorized state. • Accept—The specified port is required to be held in the authorized state.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.6.3 MAC Filtering To block an unauthorized MAC address by switch, choose Security-->MAC Filtering. The MAC blacklist shows the list of MAC addresses that are currently blocked. Figure 68 MAC Filtering MAC Address Enter a MAC address that you want add or delete from the MAC blacklist. Addresses on the blacklist will be blocked by the switch.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual MAC Address Enter a MAC address that you want add or delete from the Port Security List. Addresses on this list will be allowed access to the port. Port No. Select a port number. Add, Delete Click Add to add the address to the Port Security List, or click Delete to remove the address from the Port Security List. 6.7 Maintenance 6.7.1 Save Configuration The Save Configuration page allows you to save the current switch settings.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.7.4 Firmware Upgrade The firmware upgrade software image for the 2080E-T Switch can be obtained by contacting a Sales Representative. To upgrade the firmware from a TFTP server or a website, choose Maintenance-->Firmware Upgrade. Click the tab for the upgrade method you want to use.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.7.5 Export/Import You can back up (export) the current configuration from flash ROM to the TFTP server or a local computer connected to the 2080E-T Switch (see Figure 75). You can also recover (import) a previous backup configuration to restore the settings (see Figure 76). This saves having to manually reconfigure settings. To use the export or import function, choose Maintenance-->Export/Import.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual TFTP Server IP Address Allows you to back up the configuration file to the TFTP server. Enter the TFTP server IP. Backup File Name Enter the file name. Backup Click to backup the configuration. To backup to the TFTP server, click Backup in the upper box. To backup to the local computer connected to the 2080E-T Switch, click Backup in the lower box.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.7.6 Diagnostics Ping To ping other network devices, choose Maintenance-->Diagnostics-->Ping, enter the IP address you want to ping, and then click Active. Figure 77 Diagnostics - Ping 6.8 Troubleshooting Follow these steps to troubleshoot switch problems. 1. Verify that you are using the right power cord or adapter (DC 12–48V). WARNING Do not use a power adapter with DC output greater than 48V, or it may damage the device. 2.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Appendix A - RJ-45 PIN ASSIGNMENT The UTP/STP ports will automatically detect fast Ethernet (10Base-T/100Base-TXconnections). Auto MDI/MDIX means that the switch can connect to another switch or workstation without changing straight-through or crossover cabling. See the figures in this appendix for straight through and crossover cable schematics.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Appendix B - COMMAND SETS This appendix describes the command sets for the 2080E-T Managed Ethernet Switch. The commands are associated with a user level, described in the following key. E = User EXEC P = Privileged EXEC G = Global configuration V = VLAN database I = Interface configuration 802.1x Commands CLI Commands Level Description Example 8021x enable G Enable IEEE802.1x function.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands 8021x misc servertimeout Level Description Example G Use the 802.1x misc server timeout global configuration command to set the server timeout. switch>enable switch#configure switch(config)#8021x misc servertimeout 20 G Use the 802.1x misc max request global configuration command to set the MAX requests. switch>enable switch#configure switch(config)#8021x misc maxrequest 3 G Use the 802.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands tftp Level Description G Get configuration from TFTP server. Need to specify the IP address of the TFTP server and the file name of the image. [server IP] restore Defaults/Example switch>enable switch#configure switch(config)#tftp 192.168.1.120 restore 123.bin [file name] CLI Commands CLI Commands Level Description Example enable E Enter Privileged EXEC mode. switch>enable quit E Logout command line shell.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands dhcpserver gateway Level Description Example G Configure gateway for DHCP clients. switch>enable switch#configure switch(config)#dhcpserver gateway 192.168.1.254 G Configure DNS IP address for DHCP clients. switch>enable switch#configure switch(config)#dhcpserver dnsip 192.168.1.1 G Configure lease time (hours.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands no fault-relay Level Description G Example Disable fault relay alarm function. switch>enable switch#configure switch(config)#no fault-relay Description Example IGMP Commands CLI Commands Level igmp enable G Enable IGMP snooping function. switch>enable switch#configure switch(config)#igmp enable igmp query G Configure IGMP query mode.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual IP Security Commands CLI Commands Level Description Example security enable G Enable IP security function. switch>enable switch#configure switch(config)#security enable security http G Enable IP security of HTTP server. switch>enable switch#configure switch(config)#security http security telnet G Enable IP security of telnet server.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands no ip dhcp Level Description G Example Disable DHCP client function of switch. switch>enable switch#configure switch(config)#no ip dhcp Description Example LLDP Commands CLI Commands Level lldp enable G Enable LLDP function. switch>enable switch#configure switch(config)#lldp enable lldp interval G Configure LLDP interval.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example no mac-address-table G Remove dynamic entry of MAC address table. switch>enable switch#configure switch(config)#no mac-address-table agingtime G Configure MAC address table aging time. switch>enable switch#configure switch(config)#agingtime 30 G Auto flush MAC address table when ports link is down.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Port Control Commands CLI Commands interface fastEthernet Level Description Example G Choose the port for modification. switch>enable switch#configure switch(config)#interface fastEthernet 2 I Use the state interface configuration command to specify the state mode of operation for Ethernet ports. Use the disable form of this command to disable the port.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Port Monitoring Commands CLI Commands Level Description monitor destination Example I Configure destination port of monitor. switch>enable switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#monitor destination rx I Configure source port of monitor. switch>enable switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#monitor source rx show monitor P Show port monitor information.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands no accounting Level Description I Clear interface accounting information. Example switch>enable switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#no accounting Port Status Command CLI Commands show interface status Level Description I Show interface actual status.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Rate Limit Commands CLI Commands Level Description Example ratelimit type all I Set interface ingress limit frame type to “accept all frame.” switch>enable switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#ratelimit type all ratelimit type broadcastmulticast-flooded-unicast I Set interface ingress limit frame type to “accept broadcast, multicast, and flooded unicast frame.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example rstp forward-time G Configure RSTP forward time parameter. switch>enable switch#configure switch(config)#rstp forward-time 4 I Path cost on this interface. switch>enable switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#rstp path-cost 20 I Port priority on this interface.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands snmp trap server [IP address] Level Description Example G Configure SNMP server host information and community string. switch>enable switch#configure switch(config)#snmp trap server 192.168.1.120 community public trapversion v2c G Create a SNMPv3 user profile. switch>enable switch#configure switch(config)#snmp v3-user admin password 123 123 G Disable SNMP community strings function.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Description Example G Set offset of daylight saving time. If SNTP function is inactive, this command cannot be applied. switch>enable switch#configure switch(config)#sntp daylight-offset 60 show sntp P Show SNTP information. switch>enable switch#show sntp show sntp timezone P Show index number of time zone list. switch>enable switch#show sntp timezone no sntp G Disable SNTP function.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual System Warning Commands CLI Commands Description Example G Specified the log mode. switch>enable switch#configure switch(config)# syslog mode both G Set system log server IP address. switch>enable switch#configure switch(config)# syslog ip 192.168.1.100 show syslog P Show SYSLOG configuration and log table. switch>enable switch#configure switch#show syslog no syslog G Disable system log functon.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands qos policy Level Description Example G Select QoS policy scheduling. switch>enable switch#configure switch(config)#qos policy weighted-fair G Configure port-based priority. switch>enable switch#configure switch(config)#qos priority portbased 1 low G Configure COS Priority.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands aggregator group Level Description Example G Assign a static trunk group. show aggregator P Show information for trunk group. switch>enable switch#show aggregator 1 or switch#show aggregator 2 or switch#show aggregator 3 no aggregator lacp G Disable the LACP function of trunk group. switch>enable switch#configure switch(config)#no aggregator lacp 1 G Remove a trunk group.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands vlan port-based grpname [Group Name] Level Description V Add new port based VALN. switch>enable switch#vlan database switch(vlan)#vlan port-based grpname test grpid 2 port 2-4 or switch(vlan)#vlan port-based grpname test grpid 2 port 2,3,4 V Show VLAN information. switch>enable switch#vlan database switch(vlan)#show vlan 2 V Delete port base group ID.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands vlan 8021q port [PortNumber] Level Description V Assign a qinq link for VLAN by port. If switch>enable the port belongs to a trunk group, this switch#vlan database command cannot be applied. switch(vlan)#vlan 8021q port 3 hybridlink-qinq untag 4 tag 3,6,8 or switch(vlan)#vlan 8021q port 3 hybridlink-qinq untag 5 tag 6-8 V Assign a access link for VLAN by trunk group.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Appendix C - GLOSSARY Term Definition AWG American wire gauge (AWG), also known as the Brown & Sharpe wire gauge, is a standardized wire gauge system used predominantly in the United States and Canada for the diameters of round, solid, nonferrous, electrically conducting wire. Bandwidth The maximum data transfer speed available to a user through a network.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Term Definition IP Address A 32-bit number that identifies each sender or receiver of information that is sent across the Internet. An IP address has two parts: an identifier of a particular network on the Internet and an identifier of the particular device (which can be a server or a workstation) within that network.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Term Definition SNMP Trap SNMP traps are notifications or messages sent by a networked device to a management system. The messages are sent over the UDP protocol. The SNMP trap includes the IP address of the sender, the generic ID, specific ID, OID and corresponding value.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Notes 94 www.cooperbussmann.com/wirelessresources Rev Version 1.
Customer Assistance North America & Latin America Technical Support: United States:+1 866 713 4409 Australasia.: +61 7 3352 8624 Other: +1 604 944 9247 Email: ELPRO-Support@cooperindustries.com Website: www.cooperbussmann.com/wireless Australasia Fax: +61 7 33528677 US Fax: +1 925 924 8502 Online Resources Visit www.cooperbussmann.com/wirelessresources for the following resources and more: • User Manuals • Installation Guides • Configuration Software • Datasheets • Dimensional Drawings 5735 W.