User Manual

Read/Write Command Parameter Structure Data Index Description
r_ .. _ / w_ .. _
60 0 cfgTable gnCorVal --
61 0 cfgTable gnRefTemp --
62 0 cfgTable gnRefVal --
63 0 cfgTable crtSourceVal2 --
64 0 EEData linTable2 0
65 0 EEData linTable2 1
66 0 EEData linTable2 2
67 0 EEData linTable2 3
68 0 EEData linTable2 4
69 0 EEData linTable2 5
70 0 EEData linTable2 6
71 0 EEData linTable2 7
72 0 EEData linTable2 8
73 0 EEData linTable2 9
74 0 EEData linTable3 10
75 0 cfgTable ofCorrVal --
76 0 cfgTable ofRefTemp --
77 0 cfgTable gnCorVal --
78 0 cfgTable gnRefTemp --
79 0 cfgTable gnRefVal --
80 0 cfgTable crtSourceVal3 --
81 0 EEData linTable3 0
82 0 EEData linTable3 1
83 0 EEData linTable3 2
84 0 EEData linTable3 3
85 0 EEData linTable3 4
86 0 EEData linTable3 5
87 0 EEData linTable3 6
88 0 EEData linTable3 7
89 0 EEData linTable3 8
90 0 EEData linTable3 9
91 0 EEData linTable3 10
100 0 intData rawValue rawValue read only
101 0 intData linValue linValue read only
102 0 intData actValue actValue read only
103 0 intData actP actP read only
104 0 intData actI actI read only
105 0 intData actD actD read only
106 0 -- FWVersion FWVersion read only
107 0 -- actChipTemp actChipTemp read only
108 <nnnn> -- Mess-Strom -- current source adjust-
ment
109 0 -- actSetValue -- set value for ramp func-
tion
150 <nnnn> testPWM -- -- sets constant pwm va-
lue
> controller is OFF !!
151 <nnnn> testMinTemp -- -- lower temperature limit
with constant pwm va-
lue
152 <nnnn> testMaxTemp -- -- upper temperature limit
with constant pwm va-
lue
160 0 -- dispVal -- displayed value, de-
layed against actual va-
lue because of additio-
nal filtering
ATTENTION. misuse of caommand 150 to 152 can cause overheating or fire hazard,
use on your own risk
CoolTronic GmbH Operation Manual Peltier Controller TC2812 Page 15 / 16
Revision: 1.15, Date: 30. Januar 2008 20080130_TC2812_MAN_E