Service manual
15
4
Parts Specifications
Indoor Units
No. PARTS NAME TYPE SPECFICATIONS
1 Fan Motor MMF-230-36A Output (rated) 36W, 6 pole, 230V, 1 Phase 50Hz
2 Running Capacitor – fan motor EVM45M305UF AC 450V, 3.0µF
3 Pulse Motor Valve EDM-B60YPTF-7B-A Capacity: 60
4-Way Cassette: MM-U140
No. PARTS NAME TYPE SPECFICATIONS
1 Fan Motor MMF-230-36A Output (rated) 36W, 6 pole, 230V, 1 Phase 50Hz
2 Running Capacitor – fan motor EEP2W255HQA113 AC 450V 2.5µF
3 Pulse Motor Valve EDM-B40YPTR-7B-A Capacity: 40
4-Way Cassette: MM-U112
No. PARTS NAME TYPE SPECFICATIONS
1 Fan Motor MMF-230-28A Output (rated) 28W, 6 pole, 230V, 1 Phase 50Hz
2 Running Capacitor – fan motor EEP2W205HQA107 AC 450V 2.0µF
3 Pulse Motor Valve EDM-B40YPTR-7B-A Capacity: 40
4-Way Cassette: MM-U080
No. PARTS NAME TYPE SPECFICATIONS
1 Fan Motor MMF-230-28A Output (rated) 28W, 6 pole, 230V, 1 Phase 50Hz
2 Running Capacitor – fan motor EEP2H105HQA105 AC 500V 1.0µF
3 Pulse Motor Valve EDM-B40YPTR-7B-A Capacity: 40
4-Way Cassette: MM-U056
No. PARTS NAME TYPE SPECFICATIONS
4 Transformer TT-03-1 DC 16.3V 0.5A/AC 11.6V 0.15A
5 Pulse Motor EDM-MD12TF-3 DC12V
6 Pressure Sensor 150/100NH6-D Power Voltage DC 12V
7 Sensor for room temperature TA
Maximum input °C 25 50
38mA (at 25°C) kΩ 10 3.45
8 Sensor for heat exchanger Tc1
Maximum input °C -12 0 25 50
34mA (at 25°C) kΩ 62.3 32.8 10 3.6
9 Sensor for heat exchanger Tc2
Maximum input °C 0 25 50
26mA (at 25°C) kΩ 34.6 10 3.4
10 Control PCB CM**C02 AC 220-240V
11 Power PCB P**RC01 AC 220-240V
4-Way Cassette: MM-U140, MM-U112, MM-U080, MM-U056