manual

6
5.2.ShortCircuitProtection
Ashortcircuitplacedonanyoutputshallcausenodamageorthepower
supplyshallshutdown.(Thecontactresistanceis0.05ohmwhenoutputs
shortcircuit.)
5.3.ProtectionReset
Whenthepowersupplylatchesintoshutdownconditionduetoafaulton
anoutput,theprotectionshallresetafterthefaulthasbeenremoved.Use
remoteon/offcontrolorrecycletheACpoweragainforatypicalof3seconds.
5.4.OverShoot
Anyoutputovershootatturnonshallbelessthan10%ofthenominaloutput
value(withresistiveload)asdescribedinsec.4.1.
5.5.OverPowerProtection
At115/230VacinputthepowersupplywillshutdownallDCoutputwithin
110%to160%offullload.
5.6.OverTemperatureProtection
Thepowersupplyshallgotolatchwhenitsinnerteperaturereaches100
degreeC.
6.Enviroment
6.1.Operation/StorageTemperatureRange
Operation:0to50
C
Storage:-20to80
C
6.2.SmartTemp.ControlFeature(Option)
60degreeCorabove,thegreenledgoesoffandtheyellowoneturnson,
fanthatispoweredbythepowersupplythroughabig4pinmale
25 50 C
LOAD
100%
70%
25 50
LOAD
100%
70%
25 50
LOAD
100%
70%
100%
70%
25 5025 50
C
C
C