manual

2
InputRange
100~120Vac
VoltSelectorSet
115
200~240Vac 230
3.InputRequirements
3.1.InputVoltage
Thepowersupplyshallbeoperatedattherangebelow:
3.2.Frequency
Theinputfrequencyrangeisfrom47Hzto63Hz.
3.3.InrushCurrent
Themax.inrushcurrentis45Afor115Vacand70Afor230Vac,respectively.
3.3.1.ColdStart
Conditions Limits
Conditions Limits
Model
ACInput
FL-550ATX(CF-300)
FL-350ATX(CF-350)
FL-420ATX(CF-400)
FL-480ATX(CF-480)
115Vac
230Vac
10A 5.5A
115/230Vac,fullload,
ambient25degreeC
NOcomponentoverstressordamage
shouldoccurtothepowersupply.
Inputfuseshallnotblow.
Turnoffat132/264Vacfull
loadfor1secretarythenturn
onatthepeakoftheinput
voltagecycleat25degreeC.
NOcomponentoverstressordamage
shouldoccurtothepowersupply.
Inputfuseshallnotblow.
3.5.Efficiency
Thepowersupplyefficiencyshallnotbelessthan75%atthemaximum
loadofsection4.2and115/230Vacinputvoltage.Whileathalfloadthe
valueshallreach77%min.
3.4.ACInputCurrent
3.3.2.WarmStart
8A 4A