Instruction Manual
Table Of Contents
3.
Connecling gas hose lo
P200
Depending on your region the hose may be preassembled.
3a. Connecling gas hose directly lo
P200
4.
Connecting to gas tank
&
WARNING
Please always keep the gas bottle in upright positi on.
• The size for 20 lbs LP gas cylinder is 12.2 inches in diameter and 17.9 inches tall
Il the applian ce is not in use. the gas must be turned off al the supply cylinder.
• The cylinderused must include a collar l o protect the cylinder valve.
The minimum distance for the appl iance and the 20Ib gas tank is 40 inches apart
3b
i).
Connecling barb lo
P200
PATIO GAS REGULATOR
This is a push-on gas fitting. Ensure that the black switch is in
the horizontal posit ion. Depressthe bullan located below the
black switch and press the regulator on lo the tank valve until
it locks int a place.
POL GAS REGULATOR
This gas fitting is counterclockwise. Make sure that the tank
is completely switched off and screw the regulator as far as
p
ossible inta the gas tank valve.
3b
ii).
Connecling gas hose lo barb
CONNECTING THE LIQUID PROPANE GAS CYLINDER
1.
To connect the liquid propane gas cylinder :
2.
The cylinder valve should be in
OFF
position.
3.
Make sure the burner valve is in
OFF
position.
4.
lnspect the valve connections. port and regulator assembly. Removedebris and inspect the hose for damage.
5.
When connecting the regulator assembly lo the valve. use your hand l o tighten the nut clockwise until it stops.
Use of a wrench could damage the quick coupling nut and result in a hazardous situation.
6.
Open the cylinder valve fully by turning the valve counterclockwise.
7.
Before lighting the oven, use a soap and water solution l o check all connections for teaks.
8.
Ila teak is found, turn the cylinder valve OFF, and do not use the oven until local liquid propane dealer can make repairs.
CONNECTING THE LIOUID PROPANE GAS CYLINDER
1.
Turn the oven burner valve OFF and make sure the oven is cool.
2.
Turn the liquid propane cylinder valve OFF byturning clockwise until it stops.
3.
Detach the regulator assembly from the cylinder valve by turning the quick couplingnut counterclockwise.
4.
Place dust cap for cylinder valve outlet wheneverthe cylinder is not in use.
4 5
0