Full Product Manual
Rev: 2019 – 1A ©2019 Store It Cold, LLC 11
STEP 7 Use a pen/pencil to open a small gap in the fins about 1” from the bottom and near the center (horizontally),
between the bottom and second horizontal cooling pipes.
Take the cable sensor coming from the CoolBot Pro port labeled “Fins” and gently insert just 1/4 inch (0.7
cm) of the TIP into the small gap.
DO NOT force the sensor in, you'll damage it.
Do not touch a coolant pipe with the Fins Sensor.
You want to be between the bottom 2 horizontal cooling pipes.
Pinch the fins lightly around the sensor to keep it in place.
STEP 8 If you do not have Wi-Fi skip this step and go to STEP 9.
Mount the CoolBot Jumper outside of your cooler in a location close enough for the provided Data Cable
to connect the CoolBot Pro to the CoolBot Jumper.
The CoolBot Jumper is not weatherproof. If it is to be mounted outdoors where rain, snow, and sunlight
may get to it, then install it inside of a weatherproof nonmetallic container.
After your CoolBot Jumper is mounted, connect the CoolBot Pro and the CoolBot Jumper using ONLY the
provided Data Cable.
ATTENTION!
The provided Data Cable is specific to the CoolBot Pro/Jumper – standard phone cable will not work and may
damage your CoolBot Pro/Jumper.
STEP 9 Turn your A/C ON. Set the A/C on “COOL” Mode and set the Fan on “HIGH” speed. Set the A/C temperature
to the lowest setting. Plug in your CoolBot Pro power supply.
STEP 10 To set the temperature on your CoolBot Pro, press the checkmark button – the current set temperature
will blink. Use the right or left arrows to set the temperature to the desired value. Press the checkmark to
save the value.