Full Product Manual

11
6.2 Repair procedures (continued)
Pump Replacement
GLACIER-18 (CS5-16-VD-TB, CS5-18-VD-TB2)
1. Loosen PVC Union
2. Remove pump and PVC pipe
3. Unplug the cord from the top of the pump by removing 2 screws
4. Unscrew PVC pipe from the pump
5. Reverse steps 1-4 to reinstall the new pump
6. Reinstall cooling pads and guards, reconnect power, and test pump
GLACIER-18 (CS5-16-VD, CS5-18-VD) - AVALANCHE-36 (CS6-36-1D, CS6-36-VD)
BLIZZARD-50 (CS6-50-VD)
1. Unscrew fitting from pump
2. Unplug the cord from the top of the pump by removing (2) screws
3. Remove pump from water sump and install new pump
4. Reverse the above procedures to reconnect the wiring, lift pump bracket and reconnect the hose.
Secure wires to fan frame with wire ties to clear the fan blades. Be sure to position the plug correctly.
5. Reinstall cooling pads and guards, reconnect power and test pump.
6.3 Technical support
Technical support and service are available directly from your distributor or the COOL-SPACE Technical
Support Line at 1-800-557-5716, support@cool-space.com
or www.cool-space.com
7.0 Warranty
The limited warranty is sixty (60) months from date of invoice. Refer to the manufacturer’s Warranty Policy
for details. (Applies to units purchased after January 1, 2017)
7.1 Warranty Form
You must register your COOL-SPACE Portable Evaporative Cooler within fifteen (15) days of initial purchase to
validate your cooler’s warranty. You may register online at www.cool-space.com
.
7.2 Warranty Parts
Warranty replacement parts are available through your local distributor or supplier where you purchased your
COOL-SPACE unit. If you have any questions or concerns, please contact us direct at 1-800-557-5716 or at
sales@cool-space.com
. Please have your model number and serial number ready.
DO NOT DISCARD FAULTY PARTS Check with the Manufacturer as they may need to be
returned for warranty credit.