4.0 OPERATING PROCEDURES
There are 3 factors to consider when determining where to place the
CO O L-SPACE un it.
1. Fresh air supply: The inlet of the unit (mesh sides) require
a constant, uninterrupted supply of fresh air for maximum
performance. A distance of 3 feet clear space to any obstructions at
the rear or inlet side of the unit is recommended.
2. Discharge air ow: The cool air
discharged from the unit should
be free of obstruction to allow
the air to circulate in order to
maximize the cooling zone.
3. Ventilation: In order to operate
at maximum effectiveness, it
is helpful to have provisions to
remove the air discharged from
the unit from the cooling area.
This ensures that the unit does
not recirculate air that has already
been through the evaporative
cooling process.
The unit must be placed on a level surface to operate correctly.
Units create an oval shaped air pattern. Obstacles such as racks and
workbenches may interfere with the air flow. An attempt should be made
to locate the unit in such a manner that interruption of the air pattern is
held to a minimum. Multiple units may be required to cover larger areas.
4.1 FILLING THE UNIT WITH WATER
Once the COOL-SPACE unit has been connected to a water source as
described in 3.1, turn the water supply valve on and the unit will fill with
water. The float valve will shut off the water flow when the sump is full.
!
CAUTION
Prolonged use of hard water without proper water treatment will create
mineral deposit build up causing pump to fail which is not covered by
warranty.