Full Product Manual

Page 10
6.0 TROUBLESHOOTING/REPAIR
6.2 TROUBLESHOOTING GUIDES (CONTINUED)
WATER DISTRIBUTION SYSTEM
The water distribution system
consists of two (2) assemblies:
1. The Water Inlet Assembly
Brass bulkhead fitting
Float valve assembly
2. The Hose and Valve
Assembly
Drip Channel
Valve Assembly
Connection Hose
Floor at side of unit is wet
Water inlet hose is loose at
supply hose or inlet hose is
loose at bulkhead tting.
Tighten connections and/or
replace hose washers.
Water overflows from reservoir
Float valve hose is loose at
bulkhead tting or at oat
valve.
Tighten connections and/or
replace hose washers
Water pressure is too high to
allow oat valve to shuto
(120psi max)
Reduce water pressure by adding
an inline reducer
Float valve not properly seated
Check all hoses for leaks
Water spitting from the unit
Check The Hose and Valve
Assembly
Reduce flow control setting
Replace cracked hose and
valve assembly
Tighten hose connections
Water leaking from drain plug
Check that plug is tightly
seated in hole
Tighten drain plug
Replace drain plug
Too many dry streaks on the
pads
Check for blocked holes in the
drip channel or adjust water
ow
Remove and clean tube and
holes
Open water flow control valve
Unit will not fill
Check oat
screen
Clean
Float not
functioning
Replace