Use and Care Manual

3
CAUTION
Do not connect the COOL-SPACE® unit to any water source where water pressure
exceeds 60 psi. This will cause permanent damage to the unit.
3.2 Connecting the electrical supply:
All models utilize standard 120-volt power supply. The unit should be plugged into a
fused or circuit breaker protected 20 amp, 120 volt, 60 Hz circuit. If the unit is for
overseas operation or is custom built for a specific application, please consult the factory
for proper configuration. A ground fault circuit interrupter protected circuit is strongly
recommended.
IMPORTANT
The COOL-SPACE® unit should be plugged into a fused or circuit breaker protected 20
amp, 120 volt, and 60 Hz circuit. If the unit is for overseas operation or is custom built for
specific application, please consult the factory for proper configuration.
If an extension cord is required, refer to Table 2 for the proper 3-conducter heavy-duty
cord required. Table 1 shows the amperage requirements for the specific models.
excessive voltage drops, which cause the electric motors to generate excessive heat. This
condition results in inefficient motor operation and premature motor failure, WHICH
WILL VOID THE WARRANTY.
Table 1. Electrical requirements for US operation
CS Model Number
Volts ± 10%
Frequency (Hz)
Running Amps
16VD
115
60
4.05
361D
120
60
7.2
363B
120
60
9.7
36VD
120
60
7.05
482D
120
60
12.5
Table 2. Cord size requirement based on length and max amp draw
Length
Cord Size
Ft.
16 Ga
14 Ga
12 Ga
10 Ga
25
13 A
15 A
15 A
15 A
50
13 A
14 A
15 A
15 A
100
10 A
12 A
13 A
15 A
A-Amps at 125 volt (Derate for lower voltage)