Full Product Manual
Page 8
5.0 MAINTENANCE AND STORAGE
!
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect the power supply before performing any service or maintenance.
Failure to do so may result in serious injury or death.
5.1 REMOVING THE COOLING MEDIA TO ACCESS THE INSIDE OF THE UNIT
In order to perform any maintenance on internal components, the cooling pads must be removed to access the inside
of the unit.
1. Remove the bolts connecting the pad retainer bar (pad-side) from the housing.
2. Remove top pads on CS6-36 and CS6-50 units.
3. Starting with the center pad(s), tilt pads from the top; lift out of the unit.
NOTE: Reinstall pads correctly according to the markings on the pads.
5.2 DAILY MAINTENANCE
IMPORTANT
When shutting down the COOL-SPACE unit at the end of each use, the pump should be turned o approximately 15
minutes before the fan is turned o. This will allow the pads to drain and dry out. To avoid disguring the housing the
unit should be drained after every use. These simple guidelines will ensure long and ecient pad life as well as help to
control mildew and bacteria growth, and unit longevity.
5.3 PERIODIC MAINTENANCE
Depending on how often the COOL-SPACE unit operates, this procedure should be performed anywhere from every
week for heavy use to monthly for light use. Shut down the unit and drain the water sump. The cooling pads act as
a ltering agent and remove dust and other particles from the incoming air stream. These particles will ow into the
sump and collect there. Water impurities in the water will also collect in the sump. Maintenance tablets are available at
www.cool-space.com.
DRAINING THE WATER SUMP
1. Close the water ow valve and open the drain valve or remove drain plug located at bottom of reservoir.
2. Run pump until sump is dry then immediately shut o pump.
3. Turn unit o and disconnect the power supply.
4. Remove cooling pads, refer to section 5.1.
5. Clean out reservoir with either a towel or wet/dry vacuum.
6. Remove the water spray bar and its plug. Insure holes are free of debris.
7. Reinstall pads and pad retainer.
To keep the COOL-SPACE unit operating at peak eciency, ensure that the cooling pads are kept clean and dust-free.
Dust and other particles have an adverse eect on the media’s ability to introduce water into the air stream. If the pad
surface becomes dirty or dusty, clean with a soft brush and water.
5.4 STORAGE
1. Remove the pads, as described in section 5.1
2. Clean with a soft brush and water to remove dust and debris (never use bleach)
3. Drain sump using procedure described in section 5.3 and wipe dry
4. Store in a dry area and cover to prevent dust build-up. Covers can be found online at www.cool-space.com.