4.0 OPERATING PROCEDURES
There are 3 factors to consider when determining where to place the COOL-SPACE unit.
1. Fresh air supply: The inlet side of the unit (pad side) requires a constant, uninterrupted supply of fresh air for
maximum performance. A distance of 3 feet clear space to any obstructions at the rear or inlet side of the unit is
recommended.
2. Discharge air ow: The cool air discharged from the unit should be free of obstruction to allow the air to circulate
in order to maximize the cooling zone.
3. Ventilation: In order to operate at maximum eectiveness, it is helpful to have provisions to remove the air
discharged from the COOL-SPACE unit from the cooling area. This ensures that the COOL-SPACE unit does not
recirculate air that has already been through the evaporative cooling process.
The unit must be placed on a level surface to operate correctly. Units create an oval shaped air pattern. Obstacles such
as racks and workbenches may interfere with the air ow. An attempt should be made to locate the unit in such a
manner that interruption of the air pattern is held to a minimum. Multiple units may be required to cover larger areas.
4.1 FILLING THE UNIT WITH WATER
Once the COOL-SPACE unit has been connected to a water source as described in 3.1, turn the water supply valve on
and the unit will ll with water. The oat valve will shut o the water ow when the sump is full.
4.2 STARTING THE FAN
Set the fan switch to the “ON” position and adjust the speed to your preferred setting.
4.3 STARTING THE PUMP AND ADJUSTING THE WATER FLOW
The cooling media in your new unit will take some time to become completely saturated. During this time an odor may
emanate from them. Flush the pads with the Flow Control Valve as far open as possible - without spilling water onto
the oor - for at least 12 hours. This will ensure the best eciency of your COOL-SPACE unit. During this time, the smell
should also dissipate. For best results change the water in the reservoir frequently.
Once your pads are fully ushed
1. Fill reservoir with water
2. Turn on fan
3. Adjust water ow with Flow Control Valve until water streams over pads
Do not ood the pads with water. You should see several dry streaks on the face of the pads 1-2 in. wide. If dry
streaks grow wider, adjust ow to allow more water.
!
CAUTION
Prolonged use of hard water without proper water treatment will create mineral deposit build up causing the pump
to fail which is NOT COVERED BY WARRANTY
IMPORTANT
Pump is equipped with LOW WATER CUT OFF which may take up to 5 minutes to reset each time.