6.0 TROUBLESHOOTING/REPAIR
6.4 PUMP REPAIR PROCEDURES
!
CAUTION
Repairs should be performed by a qualied technician!
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect the power supply before performing any service or maintenance.
Failure to do so may result in serious injury or death.
PUMP REPLACEMENT FOR CS518VDTB2
1. Loosen PVC Union
2. Remove pump and PVC pipe
3. Unplug the cord from the top of the pump by removing 2 screws
4. Unscrew PVC pipe from the pump
5. Reverse steps 1-4 to reinstall the new pump
6. Reinstall cooling pads and guards, reconnect power, and test pump
PUMP REPLACEMENT FOR CS518VD, CS6361D, CS636VD, CS650VD
1. Unscrew tting from pump
2. Unplug the cord from the top of the pump by removing (2) screws
3. Remove pump from water sump and install new pump
4. Reverse the above procedures to reconnect the wiring, lift pump bracket and reconnect the hose. Secure wires
to fan frame with wire ties to clear the fan blades. Be sure to position the plug correctly.
5. Reinstall cooling pads and guards, reconnect power and test pump.
6.5 TECHNICAL SUPPORT
Technical support and service are available directly from your distributor or the COOL-SPACE Technical Support Line at
1-800-557-5716, support@cool-space.com or www.cool-space.com.