OPERATION AND MAINTENANCE MANUAL 120V/60HZ GLACIER AVALANCHE BLIZZARD CS5-18-VD CS6-36-1D CS5-18-VD-TB2 CS6-36-VD CS6-50-VD
CONTENTS 1.0 INTRODUCTION..................................................................................................................................................4 2.0 UNPACKING YOUR COOL-SPACE UNIT...........................................................................................................4 3.0 SET-UP OF THE COOL-SPACE UNIT.................................................................................................................4 3.1 Connecting the water supply.................
SIGNAL WORD DEFINITIONS ! DANGER DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. ! WARNING WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. ! CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
3.0 SET-UP 3.2 CONNECTING THE ELECTRICAL SUPPLY IMPORTANT The COOL-SPACE unit should be plugged into a fused or circuit breaker protected 15 amp, 120 volt, and 60 Hz circuit. All models utilize standard 120-volt power supply. The unit should be plugged into a fused or circuit breaker protected 15 amp, 120 volt, 60 Hz circuit. Table 1 shows the amperage requirements for the specific models. If an extension cord is required, refer to Table 2 for the proper 3-conductor heavy-duty cord required.
4.0 OPERATING PROCEDURES There are 3 factors to consider when determining where to place the COOL-SPACE unit. 1. Fresh air supply: The inlet side of the unit (pad side) requires a constant, uninterrupted supply of fresh air for maximum performance. A distance of 3 feet clear space to any obstructions at the rear or inlet side of the unit is recommended. 2.
4.0 OPERATING PROCEDURES 4.4 INTUITIVE CONTROL PANEL™ OPERATION The BLIZZARD-50 comes equipped with the Intuitive Control Panel™. Power Indicator Red Light - Power Connected Green Light - Power On Remote Sensor Low Water Indicator Power On/Off REM Fan Fan Pump Auto/Manual Mode 15 Min.
5.0 MAINTENANCE AND STORAGE ! WARNING ELECTRICAL SHOCK HAZARD Disconnect the power supply before performing any service or maintenance. Failure to do so may result in serious injury or death. 5.1 REMOVING THE COOLING MEDIA TO ACCESS THE INSIDE OF THE UNIT In order to perform any maintenance on internal components, the cooling pads must be removed to access the inside of the unit. 1. Remove the bolts connecting the pad retainer bar (pad-side) from the housing. 2.
6.0 TROUBLESHOOTING/REPAIR ! WARNING ELECTRICAL SHOCK HAZARD Disconnect the power supply before performing any service or maintenance. Failure to do so may result in serious injury or death. 6.1 TROUBLESHOOTING The COOL-SPACE unit consists of three systems: the fan, water distribution and pump. It is important to determine which system of the COOL-SPACE unit the problem is associated with. This may not always be obvious, in that certain problems may be associated with more than one system.
6.0 TROUBLESHOOTING/REPAIR 6.
6.0 TROUBLESHOOTING/REPAIR WATER SYSTEM PUMP The water distribution system consists of two (2) assemblies: PUMP MOTOR WILL NOT RUN WHEN SWITCH IS TURNED ON 1. The Water Inlet Assembly Turn fan on to check for power •If • fan doesn’t start check breaker and cord plug-in •If • fan does start; check for power to and through pump switch (when turned on) Ensure water level is high enough to make the lowwater cut-off circuit Fill water reservoir •Brass • bulkhead fitting •Float • valve assembly 2.
6.0 TROUBLESHOOTING/REPAIR 6.3 FAN REPAIR PROCEDURES ! CAUTION Repairs should be performed by a qualified technician! ! WARNING ELECTRICAL SHOCK HAZARD Disconnect the power supply before performing any service or maintenance. Failure to do so may result in serious injury or death. FAN MOTOR REPLACEMENT FOR CS5-18-VD, CS5-18-VD-TB2 1. Remove cooling pads (see section 5.1 for pad removal instructions) 2. Remove the black motor wiring plate and disconnect motor wires.
6.0 TROUBLESHOOTING/REPAIR 6.4 PUMP REPAIR PROCEDURES ! CAUTION Repairs should be performed by a qualified technician! ! WARNING ELECTRICAL SHOCK HAZARD Disconnect the power supply before performing any service or maintenance. Failure to do so may result in serious injury or death. PUMP REPLACEMENT FOR CS5-18-VD-TB2 1. Loosen PVC Union 2. Remove pump and PVC pipe 3. Unplug the cord from the top of the pump by removing 2 screws 4. Unscrew PVC pipe from the pump 5.
7.0 WARRANTY The limited warranty is sixty (60) months from date of invoice. Refer to the manufacturer’s Warranty Policy for details. (Applies to units purchased after January 1, 2017) 7.1 WARRANTY FORM You must register your COOL-SPACE Portable Evaporative Cooler within fifteen (15) days of initial purchase to validate your cooler’s warranty. You may register online at www.cool-space.com. 7.