6.2 Repair procedures
Repairs should be performed by a qualified technician!
ELECTRICAL SHOCK HAZARD
Disconnect the power supply before performing any service or maintenance on the unit.
Failure to do so may result in serious injury or death.
Fan Motor Replacement
GLACIER18 (CS5-16-VD, CS5-16-VD-TB, CS5-18-VD, CS5-18-TB)
1. Remove cooling pads (see section 5.1 for pad removal instructions)
2. Remove the black motor wiring plate and disconnect motor wires. (Mark each wire with a
marker or marker tape to allow for easy matching when installing new motor.
3. Remove the (4) nuts and bolts that mount the motor, fan, and support braces (complete
fan assembly).
4. Replace new fan assembly.
5. Secure with 4 nuts and bolts.
6. Replace any wire ties that were removed when taking out the old fan assembly.
7. Replace the black motor wiring plate.
8. Reinstall pads and connect power
AVALANCHE36 (CS6-36-1D, CS6-36-VD)
BLIZZARD50 (CS6-50-VD)
1. Remove cap from bottom of motor. Disconnect wires. Clip wire ties.
2. Remove (4) fan mounting bolts from the front. (Support fan to ensure it doesn’t fall.)
3. Pull the fan out of the unit.
4. Remove blade mounting nut and blade.
5. Remove mounting arms by loosening (8) bolts holding the arms to the motor. (Make
note of arms positions for reinstallation.)
6. Install arms and blade on new motor.
7. Install fan in opening and secure with mounting bolts.
8. Reconnect wires and tie cord to motor arm to keep them out of fan.