Use and Care Manual

7 / 18
Make sure exhaust hose assembly is securely attached by clips in exhaust outlet to avoid it falling off.
1.3 Installation of window seal-plate
1. Install the rectangle end of exhaust hose adapter into the corresponding rectangle hole in window seal-plate
assembly, fix it with screw. (Figure B. in Photo below).
A. Align the 4 openings on window seal-plate with corresponding 4 tabs on exhaust hose adapter and set them
together. Slide window seal plate downwards onto the exhaust adapter.
B. Lock self-tapping 4 mm screw into adapter hole. See pictures below.
Remarks:
Slide the adapter downward, and assure the pieces are aligned in proper position.
Screw the two components together to ensure the connection.
Exhaust hose should not be bent more than 45°, in order to keep good ventilation of exhaust hose.
Figure B.
.
Installation of window venting kit
The Venting kit must be installed in order for the unit to work correctly in the air conditioning mode.
The venting kit does not need to be used in the fan only mode. This window kit has been designed to fit
most vertical and horizontal window openings. The window kit can also be used in sliding door, with
additional components, not included.
1. Choose a suitable location, near a grounded electrical outlet, and a suitable window or door.
2. Open the window or door and adjust the length of the window kit to fit the opening. The kit should fit into the