Use and Care Manual
14 / 18
Handling Position
Air outlet
The compressor motor will turn off when the compressor is running for over 10 minutes and tube temperature
inside the compressor is continuously ≦36℉ for 20 seconds while in cooling mode. An error code of E4 will show
on the LED display window, and the unit initiates the anti-frost protection. All buttons on control panel (except for
power button) are inactive.
Once the tube temperature inside the compressor is ≧46℉, the protection is relieved to recover into original
status, and the compressor will continue to run after a 3 minute delay. See Delay Protection feature below.
2. Water-full safety alarm and shut –off protection function:
Warning will sound when water reaches its alarm level in water tank, and unit will automatically stop operation.
Both water-full indicator and “FL” on LED window will be flashing. You will need to drain the excess water in the
unit, before continuing operation. (For more information about how to drain, refer to the “Drainage Instruction”
please).
3. Delay protection function of compressor
This unit offers restart protection to compressor. There is 3-minute start delay after compressor is shut down.
Handling and Transportation
1. Handling and moving the unit
Hold the top of the air outlet window in front panel with one hand, and the handle at the top of the back panel with another
hand, then move the unit in upright position (As shown in Photo below).
Note:
Do not hold the horizontal louvers by hand.
Keep the unit in the upright position whenever handling or moving it.
If unit has been in operation, drain the water in the unit completely before moving the unit.
Take away the remote control before handling or moving the unit
.
Drainage Instruction
1. Manual drain: