Specifications

21
High-density graphite tube
206-50587
Pyro-coated graphite tube
Platform tube
206-50588
Select one of the three types of graphite tubes according to the aim of the analysis.
206-50887-02
MAF-106S compressed gas regulator
040-72019-21
Argon gas cylinder
I
Specifications
GFA-7000 graphite furnace atomizer 206-77700-XX
For Furnace Analysis
For cooling GFA, 100 VAC, 1100VA
CA-1114A-1 cooling water circulation unit
044-01809-07
For connecting GFA and CA-1112Cooler connection kit
Parts for cooling water connections
206-84373-91
Connecting tubes when using tap water to cool GFA
Cooling water tube ASSY 206-51028-91
Decompression valve when using tap water to cool GFA
Regulator ASSY 206-86147-91
Heating control system: Drying: Digital current control
(with automatic temperature calibration function)
Ashing, atomization: Digital temperature control via
optical sensor
Heating temperature range: Ambient to 3000 °C
Inner gas type: Dual automatic switching type
Inner gas flow rate: 0 to 1.50 L/min, 0.01 L/min increments
Ar gas: 3.5 L/min max.
Cooling water: Cooling water circulation unit or tap for process water
Water temperature: 10 to 30 °C, flow rate: 0.6 to 1.5 L/min
* Separately order the parts below.
Part Name P/N Remarks
Optional Accessories / Related Products
Flow meter kit
206-77617-91 Float-type flow meter for support gas
Dimensions: 250 W × 130 D × 170 H mm
206-77655-91 Vial mounting platform: 220 W × 95 D mm
Vial positions: 5-step switching
For Flame Analysis
Sample platform
208-91753-91
Air compressor
208-91750-36 100 VAC, 50/60 Hz, with mist separator
100 VAC, 50/60 Hz, with mist separator
Low-noise air compressor
206-52458-91 Required if using an air compressor other than above.
Mist separator kit
040-72020-01 For C2H2
For dinitrogen oxide gas
YR-71 compressed gas regulator
040-72019-11
MAF-85S compressed gas regulator
Required to use the flame micro sampling method. ASC-7000 and
ASK-7000 (or ASC stand kit) are also required.
206-77540-91
206-50957-91
Micro sampling kit
Improves sensitivity with Air-C
2H2 flame. N2O-C2H2 flame is not applicable.
* High-salt-concentration samples may decrease the quartz tube life-span.
Atomic Booster
Provides viewing inside the graphite tube.
Including Video View Software (CD-ROM)
206-52950-91
Graphite Furnace Camera GFA-TV
O-ring set for organic solvents206-77620-92
O-ring set
Made of pure titanium. Air-cooled. 5 cm slot for N2O-C2H2 flame
High-temperature burner head
Part Name P/N Remarks
206-77530-91
.
Extremely corrosion-resistant
.
Can also be used for Air-C2H2 flame.
For flame analysis For furnace analysis
ASC-7000 autosampler 206-77600-XX
Autosampler
Required to mount ASC-7000 to conduct flame analysis only. ASC stand kit 206-77650-91
Permits both flame and furnace analysis.
ASK-7000 extension unit for furnace analysis
Required to use ASC-7000 and HVG-1. Nozzle ASSY, HVG
I
Specifications
Part Name P/N Remarks
System: Flame / furnace
Function: Zero-point detection, auto rinse, auto diagnosis, random access
Maximum reagent / sample positions: Reagents: 8 positions, samples: 60 positions
* Separately order the parts below.
206-77550-91
206-67563