User Manual: C100 9052 Long Point • Houston, TX 77055 888.827.1675 • info@coolazone.com Facebook.com/CoolAZone • Twitter.com/CoolAZone w w w . c o o l a z o n e .
Table of Contents Table of Contents & How It Works Installation & Set-Up Dust Screen & Side Panel Managing the Water Reservoir LCD Button Panel & Remote Control Basic Operation & Powering On C-100 Controls Using the Timer Feature Routine Maintenance Basic Troubleshooting Circuitboard & Specifications Contact Information Page 2 Page 3 Page 4 Page 4 Page 5 Page 6 Pages 7-8 Page 9 Page 9 Page 10 Page 11 Page 12 How Cool-A-Zone Works COOL REFRESHING AIR BLOWS OUT Cool-A-Zone’s Water Distributor HOT AIR COMES
Installation & Set-Up INSTALLATION AND INITIAL SET-UP: If the fan must be placed close to a wall or other obstacle, try to keep a distance of 2 to 3 feet between the wall or obstacle and the face of the cooling pads. When placing the fan, take the following into consideration: a. Uninterrupted fresh air should be made available to the cooling pad side of the unit for best results. b. Avoid blocking the air output (front) side of the fan. Cool air released from the unit should be able to freely circulate. c.
Dust Screen & Side Panel ACCESSING THE DUST SCREEN AND SIDE PANEL If you need to access the Dust Screen and Side Panel on your C-100, follow the instructions below. Using a Phillips (“crosshair”) Screwdriver, as follows: a. Take the eight screws off the dust screen housing as shown in the picture below (left) . b. Once the eight screws are removed, gently remove the housing and side panel to access the two (2) dust screens c.
LCD Button Panel THE LCD BUTTON PANEL The Cool-A-Zone C-100 has a user-friendly and easy-to-use LCD indication panel with one-touch button features for activating, timing, setting, and full control of your C-100. The diagram below outlines what the various buttons and indicators mean. Note that the central area (in white below) is an indication panel, whereas the grey area denotes the buttons. Pages 7 & 8 will go into detail on the various Buttons & Indicators.
Basic Operation INITIAL OPERATION After ensuring the unit has adequate water for operation and that your C-100 has been plugged in, turn the Cool-A-Zone C-100 on by pressing the power button either on the LCD Panel face or as shown on the remote control on Page 5 of this manual. POWER: Turn the device on/off Power Buttons may be found either on the right of the LCD Panel or on the Red Button of the remote control.
C-100 Controls SHOW VENITILATION SHOW AIRFLOW 5 3 SPEED BUTTON 2 POWER (ON/OFF) 1 6 4 ANION INDICATOR COOL INDICATOR COOL ON/OFF USING YOUR C-100 1 - Power Button: turns the unit ON or OFF. 2 - Speed Button: this controls the airflow. On first operation, the C-100 will be at SPEED 2 (there are three Speeds, 1 being the lowest and 3 being the highest). Pressing again will take you up to SPEED 3, then pressing it again will bring you down to SPEED 1.
C-100 Controls (cont’d) USING YOUR C-100 7 - Timer Button: Activates the C-100 TIMER feature, allowing you to either start the unit from a start-up set after a certain number hours or ANION ON/OFF TIMER 7 8 REMOTE RECEIVER 9 TEMPERATURE DISPLAY 11 SHOW VENITILATION 13 10 12 14 15 SWING ON/OFF LOW WATER TIMER SWING ANION INDICATOR INDICATOR INDICATOR INDICATOR stop the unit after a certain number of hours. More on this function on Page 9.
Using the C-100 Timer WHAT THE TIMER FUNCTION DOES: 1. 2. Starts your Cool-A-Zone C-100 cooler automatically after n hours from the stand-by state; OR, Stops your Cool-A-Zone C-100 cooler automatically after n hours after being turned ON. Note: the TIMER function can only be set by the hour. USING THE TIMER: 1. Press the TIMER button. 2. You will notice that the TIMER button begins to flicker & you will see that “H x” appears in the TEMPERATURE display. 3.
Basic Troubleshooting No. 1 Issue The C-100 Will Not Power On Possible Cause Solution Unplugged or faulty power source. Check if C-100 is plugged in, and outlet is working. Burnt Fuse. Replace Fuse. Controller breakdown. Replace Controller. Electrical Mainboard is Replace Mainboard. broken or faulty. 2 The Air is Not Cool Low or no Water. Add water. VENTILATION Mode is activated. Activate COOL Mode. COOL button not working. Replace Controller. Pump breakdown. Replace Pump.
Circuitboard Diagram Cool-A-Zone can not be held liable for any modifications made to the above circuit diagram by any party, whether purchasor or third party. DISCONNECT POWER BEFORE WORKING WITH THE FUSES OR CIRCUIT BOARD! The above diagram is provided as a reference point only for trained and skilled professionals and journeymen who have the knowledge to read circuit diagrams, understand their meaning, and make such adjustments to fuses, circuits, and the like.
Cool-A-Zone www.coolazone.com info@coolazone.com 888.827.1675 9052 Long Point Houston, TX 77055 Twitter.com/CoolAZone Facebook.com/CoolAZone w w w . c o o l a z o n e .