GENERALINSTALLATIONDATA
Thisequipmentisdesignedandsoldforcommercialuseonlybypersonneltrainedand
experiencedinitsoperationandisnotsoldforconsumeruseinandaroundthehomenorfor
usedirectlybythegeneralpublicinfoodservicelocations.
IMPORTANT
INSTALLINNONCOMBUSTIBLELOCATIONSONLY!Clearancefromnoncombustible
constructionmustbe6”frombackandsides.
WARNING:Improperinstallation,adjustment,alteration,serviceormaintenancecancause
propertydamage,injuryordeath.Readtheinstallation,operatingandmaintenance
instructionsthoroughlybeforeinstallingorservicingtheequipment.
FORYOURSAFETY:
Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisorany
otherappliance.Keeptheapplianceareaclearandfreefromcombustibles.
EXHAUSTCANOPY:
Openhearthbroilersinherentlycreateagooddealofheatandsmokeandshouldbeinstalled
underanefficientexhausthoodwithflameprooffilters.Averticaldistanceofnotlessthan48”
shallbeprovidedbetweenthetopoftheapplianceandfiltersoranyothercombustible
material.Exhaustinstallationmustconformtolocalcodes.
AIRSUPPLY:
Provisionsforadequateairsupplymustbeprovided.
ELECTRICALREQUIREMENTS:
TheCharbroilerispellet
fired;howevertheunituseselectricitytocontrolthetemperatureand
ignitethepellets.Theunitshouldbepluggedintoa120volt15ampcircuit.
SHUTDOWNINSTRUCTIONS:
Presstheon/offbuttononthecontrollertoturntheunitoff.Donounplugtheunitforatleast
15minutes.Notethatthecombustionfancontinuestooperateafterturningtheunitofffor15
minutes.Thispurgesthepelletsandashfromtheburner.