Chapter 4: Management with WebPAM PRO
77
See page 211 for instructions on what to do when any of these messages
appears.
Delete a User
1. Log into WebPAM as the Administrator.
2. Click the User Management icon under Administrator Tools. A list of
Users appears (below).
Enclosure Over
Temperature*
Enclosure is running too hot.
Enclosure Fan Stop* One of the fans has stopped working.
Enclosure 3.3 Volt out of
Range
3.3 Volt power is out of specification.
Enclosure 5 Volt Out of
Range*
5 Volt power is out of specification.
Enclosure 12 Volt Out of
Range*
12 Volt power is out of specification.
Battery Temperature Rise Battery is heating up. Battery ceases to charge above
45°C or discharge above 60°C.
Battery Temperature
Dropped
Battery is cooling down.
Battery Capacity below
threshold
Battery is too weak to function.
Battery Capacity Normal Battery is ready for use.
Battery Discharging Battery is leaking power.
Battery Charging Battery is recharging.
Battery Maintenance
Mode
Discharge and recharge to test battery condition.
Happens automatically once every two months.
Battery life ended Battery is dead. Replace it.
Item Meaning