User manual
VTrak 15200 User Manual
210
Back of Enclosure
When the FRU Status LED on VTrak’s front panel shows Amber or Red, check
the LEDs on the back of VTrak. These LEDs give the status of the field
replaceable units.
Figure 6. LEDs on the back of VTrak.
Under normal conditions, the power supply, battery and fan LEDs should display
green. Note that on VTrak 15200, the left cooling unit houses a cache-backup
battery but the right unit does not.
LEDs
State
Dark Green Amber Red
Power supply Not detected OK Fan failed Failed
Battery Not detected OK Too hot or
Low capacity
Failed
Fan 1 or 2 Not detected OK Wrong speed Failed
Power Supply
LED
iS C SI 1 i SC SI 2 M gm t
IOIOI
PROMISE
TECHNO LOGY, I NC.
VTrak 15200 Controller
Storage Enclosure
Processor (SEP)
RAID Controller
Power Supply 1 Cooling Unit 1
with Battery
Power Supply 2Cooling Unit 2
Fan 1
LED
Battery
LED
Fan 2
LED