User manual

VTrak 15200 User Manual
128
4. Press 2 and Enter to select Logical Drive ID 2. The Modify Logical Drive
Parameters submenu displays:
-------------------------------------------------------------------------
Logical Drive 2 Parameters:
Name: LogDrv2 RAID Level: 1
Stripe Block Size 64K Capacity: 35 GB
Member PDs: 3,5 Smart Check: On
Cache Policy: Write Through Retry Count: 2
Auto Rebuilding: On Hot Spare: Global
Priority: High(RBLD), High(SYNC), High(Migration)
SCSI Mapping: CH 1 LUN 1
SCSI Mapping: CH 2 LUN 1
-------------------------------------------------------------------------------
Modify Logical Drive 2 Parameters
1. SCSI Assignment
2. Cache Policy
3. Retry Count
4. Enable/Disable SMART
5. Name
6. Priority
7. Hot Spare Policy
8. Auto Rebuilding
R. Return to Previous Menu
5. From this submenu, press 7 and Enter to access the Hot Spare Policy
function.
Current hot spare policy:
Global
Change to Dedicated hot spare policy for LD 2(y/n)?>y
6. Press Y and Enter to change the Hot Spare Policy to Dedicated.
In this example, there was only one free physical drive meeting this Logical
Drive's requirements, so it was automatically chosen.