Chapter 4 Alarms
Clip Active Alarms Screen
Figure 4-1 Clip Active Alarms screen
Table 4-2 describes the alarms that could appear in the Name column.
Table 4-2 Environment Parameter Definitions
Alarm Name (Area) Definition
Alarm Type
(Name)
DWDM_ARXPOWER
(protected channels only)
Indicates that the power input from the A side of the
ONS 15200 network is outside the acceptable power
range.
Status
DWDM_BRXPOWER
(protected channels only)
Indicates that the power input from the B side of the
ONS 15200 network is outside the acceptable power
range.
Status
DWDM_RXPOWER
(non-protected channels only)
Indicates that the power input from the ONS 15200
network is outside the acceptable power range.
Status
DWDM_PELTIERCURRENT Indicates that the Peltier current of the selected CLIP
module is outside the acceptable power range.
Status
DWDM_FDI Indicates that the selected CLIP module has received
an FDI alarm from the NE upstream.
DWDM_LOC If the selected CLIP module is protected, it indicates
that the CLIP has lost input power on the A and B
sides. If the selected CLIP module is unprotected, it
indicates that the CLIP has lost input power.