Specifications
3-16
Cisco ONS 15200 Maintenance Manager Installation and Operations Guide
78-13764-01
Chapter 3 CLIP Module Configuration
Path Folder Overview
3.3.4 DCN
The DCN area of the Clip Status screen provides the CAN bus and QPP signal status. Table 3-13
describes the DCN parameters.
3.3.5 Miscellaneous
The Miscellaneous area of the Clip Status screen provides miscellaneous hardware and software alarm
information status. Table 3-13 describes the DCN parameters.
3.4 Path Folder Overview
The Path Folder Overview screen provides a graphical representation of the optical paths configured for
the ONS 15200 network (Figure 3-9). LEDs indicate active alarms on the NE. The signal direction is
indicated by the lines entering or exiting the NE. Green lines indicate inbound signals and white lines
indicate outbound signals. A red line indicates inbound signals that have alarms somewhere on the path.
Table 3-12 Clip Status - Environment
Parameter Definition
Board
Temperature
Displays the values associated with the ambient
temperature on the surface of the CLIP module.
Power Displays the status of the input power coming into the
SCU or MCU from the AC to DC converter.
Table 3-13 Clip Status - DCN
Parameter Definition
CAN alarm Displays the status of the CAN bus.
QPP A alarm
(protected only)
Displays the transmission status of the internal datacom link on the A side of the
network.
QPP B alarm
(protected only)
Displays the transmission status of the internal datacom link on the B side of the
network.
QPP alarm
(unprotected only)
Displays the transmission status of the internal datacom link of the network.
Table 3-14 Clip Status - Miscellaneous
Parameter Definition
DAC alarm A hardware fault relating to the digital/analog converter (DAC) has occurred.
Flash alarm A hardware fault relating to the eeprom has occurred.
Instruction alarm An entity is trying to write to an unavailable position.