Specifications
3-13
Cisco ONS 15200 Maintenance Manager Installation and Operations Guide
78-13764-01
Chapter 3 CLIP Module Configuration
Clip Status
Figure 3-7 Clip Status screen (unprotected)
The Clip Status screen is divided into four areas: DWDM Side, Client Side, Environment, and DCN. The
DWDM Side area lists the settings and current values of the signal from the DWDM side of the ONS
15200 system. Parameters listed in the Client Side area describes the quality of the signal received from
the client equipment. The Environment area provides the board temperature and power of the CLIP
module. The DCN area indicates any Control Area Network (CAN) or QPP alarms.
The information available on the Status screen varies, depending on whether the associated CLIP
module is configured as protected or unprotected. Figure 3-6 shows the Status screen for a protected
CLIP. The Status screen for unprotected CLIP modules shows only a general DWDM Rx Power field.
For each parameter, the following fields can be modified:
• High Alarm threshold
• High Warning threshold
• Low Alarm threshold
• Low Warning threshold
Procedure: Suppress Alarms
Follow these steps to configure alarms and warnings so they are not reported.
Caution Suppressing alarms can be service affecting.
Step 1 Select the Suppress Alarms checkbox for the alarm or warning you want to suppress. A check mark
appears in the box.