Specifications
3-11
Cisco ONS 15200 Maintenance Manager Installation and Operations Guide
78-13764-01
Chapter 3 CLIP Module Configuration
Clip Status
• Major—The selected CLIP module generated a major alarm based on a condition that exceeds a high
alarm or lower alarm threshold value.
• Critical—The selected CLIP module generated a critical alarm based on a condition that exceeds a
high alarm or lower alarm threshold value.
3.3 Clip Status
The Clip Status screen displays the operating status of the CLIP module (Figure 3-6). Table 3-9
describes the parameters found in this screen.
Table 3-9 CLIP Module Status Screen Parameters
Parameter Definition
Area Describes the type of information available.
Name Displays the name of the measurement or alarm.
Suppress Contains a checkbox to select or deselect the Suppress feature, which suppresses
the alarm in the local database. The CLIP will still send all future alarms to all
subscribers including the local database.
Inhibit Contains a checkbox to select or deselect the Inhibit feature, which inhibits the
alarm on the CLIP.
Status Describes the status of the alarm. The following values are possible:
• Normal—The selected CLIP module has not reported any alarms.
• Uninit—The Maintenance Manager did not recieve any information from the
selected CLIP module.
• Lowalarm—The CLIP module recorded an event that exceeded the lower alarm
threshold for the selected parameter.
• Lowwarning—The CLIP module recorded an event that exceeded the lower
warning threshold for the selected parameter.
• Suppressed—The selected parameter will not report its status. (Also indicated
by a selected Suppress Alarm checkbox.)
• Highwarning—The CLIP module recorded an event that exceeded the high
warning threshold for the selected parameter.
• Highalarm—The CLIP module recorded an event that exceeded the high alarm
threshold for the selected parameter.
Low Alarm Displays the lower threshold value that will cause an alarm to be generated.
Low Warning Displays the lower threshold value that will cause a warning to be generated.
Present Value Displays the real-time value of the parameter as measured by the module.
High Warning Displays the upper threshold value that will cause a warning to be generated.
High Alarm Displays the upper threshold value that will cause an alarm to be generated.
Unit Displays the unit of measure for the values of the selected parameter.