Specifications

3-6
Cisco ONS 15200 Maintenance Manager Installation and Operations Guide
78-13764-01
Chapter 3 CLIP Module Configuration
Clip Summary
3.2.2 Changing the Data Rate
Follow these steps to change the data rate for the selected CLIP module:
Step 1 Open the Clip Summary screen and double-click the Data Rate value. The Set Value screen opens
(Figure 3-4).
Step 2 Select the desired data rate from the list. Table 3-6 describes the data rate selections available.
Step 3 Click OK. The selected data rate appears on the Clip Summary screen. The change is effective
immediately.
Ta b l e 3 - 5 Clip Summary ScreenGeneral
Parameter Value
Network Element
Status
UninitThe Maintenance Manager did not recieve any information from the
selected CLIP module.
NormalThe selected CLIP module has not reported any alarms.
WarningThe selected CLIP module has reported a condition that exceeds a
high warning or lower warning threshold value.
MinorThe selected CLIP module generated a minor alarm based on a
condition that exceeds a high alarm or lower alarm threshold value.
MajorThe selected CLIP module generated a major alarm based on a
condition that exceeds a high alarm or lower alarm threshold value.
CriticalThe selected CLIP module generated a critical alarm based on a
condition that exceeds a high alarm or lower alarm threshold value.
InstalledThe NE detects the physical presence of the CLIP module, but data
from the CLIP module has not been uploaded yet. Possible causes include a
faulty connection or lack of management of the CLIP.
Not_installedThe NE has lost contact with the CLIP module.
UndefinedAn alarm was received but its content cannot be interpreted.
Protection YesThe selected CLIP modules traffic is protected on another circuit.
NoThe selected CLIP modules traffic is not protected on another circuit.
Uploaded YesWhen the CLIP was detected, all required data about the CLIP was
successfully retrieved from the CLIP.
NoWhen the CLIP was detected, all required data about the CLIP was not
successfully retrieved from the CLIP. To move the Uploaded state from No
to Yes, you can manually select Upload from the Tools/Clip menu or
right-click the specified CLIP and select Upload.
Note If this parameter is set to No, the Network Element Status value will
be Installed. Thereby the Status will not be recognized and there will
be no status information in the Explorer View (tree control).
Data Rate Describes the rate at which data is being transmitted in and by the ONS 15200
system. The operator can change this value. The Changing the Data Rate
section on page 3-6 describes the procedure for changing the data rate.