User's Manual
CSL CS101-2 EPC CLASS 1 GEN 2 RFID HANDHELD READER USER'S MANUAL, VERSION 1.0
Copyright © Convergence Systems Limited, All Rights Reserved
189
avoided. Remember to select different session numbers for readers to avoid tag replying
wrongly to other reader.
2. If dense reader mode is not required, Profile 0 should be used as it allows the fastest tag
read.
3. Adjust the power of reader to take a balance between read range and cross read effect.
4. Employ inspection process for identifying malfunction reader. For example, reading
testing tags from all readers and then collecting the read data from edge server. Analysis
of the data helps assessing the reader health.
5. Remote reboot of reader and remote control of power grid should be supported since the
readers may distribute in vast area.
6. During network failure, reader is not able to send tags read to trusted server. If Network
Failure Data Backlog is enabled, those tags are buffered in the reader. Backlog tags are
sent to trusted server after the TCP connection is re-established. Therefore, system
integrators should also provide application level failover for this feature.