User manual

GB
82
DECLARATION OF PERFORMANCE
No. Ci4-CPR-130619-SE-1
DECLARED PERFORMANCE
Essential characteristics Performance Harmonised technical
specification
Reaction to fire A1 WT
Minimum distance to combustible material 150 mm to rear
150 mm to side
According to the given conditions in the installa-
tion instructions
Risk of falling embers Approved
Emissions from combustion
Wood / (Coal briquettes)
CO 0.10% / (0.21%)
NOx 108 mg/m
3
/ (NPD)
OGC 107 mg/m
3
/ (NPD)
PM 36 mg/m
3
/ (10 mg/m
3
)
Surface temperatures Approved
Cleaning options Approved
Mechanical durability Approved
Emissions of hazardous substances Approved
Nominal output 4 kW / (4 kW)
Efficiency 78% / (76%)
Flue gas temperature in connector at nominal
output
310°C / (270°C)
EN 13229:2001 / A2:2004
PRODUCT
Product type Insert lit with solid biofuels
Type designation Contura i4
Manufacturing number See rating plate on the insert
Intended area of use Heating of rooms in residential buildings
Fuel Wood / (Coal briquettes)
MANUFACTURER
Name NIBE AB / Contura
Address Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
CHECKS
According to AVCP System 3
European standard EN 13229:2001 / A2:2004
Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,
has checked declared performance and issued test report no. RRF-29 11 2751
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Business area manager NIBE STOVES
Markaryd, 1st July 2013
CERTIFICATE