Instruction Manual

Master and Slave Wiring Connections
Revision E Bi-parting Gate Systems 5-3
1. As shown in Figure 5-2, connect a shielded communications cable to the DUAL GATE inputs in each
unit. The inputs are located near the base of the Smart DC Controller. Be sure to connect the wires in pairs
to the same terminal ports (A-A, B-B, and COM to COM) on both units. See
Master Slave Connections on
SDC Boards
Table 5-2.
2. Attach a ring terminal to the shield wire and connect it to the Smart DC Controller’s convenient ground
screw. Refer to Figure 5-2.
NOTE
Connect the ground shield wire to only one operator, not both.
Table 5-2. Master Slave Connections on SDC Boards
Slave Master
AA
COM COM
BB
Shield wire to Ground* * Only ground to one
unit. Do NOT attach the
shield wire to both units.