Instruction Manual

Installer Menu
3-28 SwingSmart DC Installation and Reference Manual Revision E
26
0 = Hold open only
1 = Hold close and hold
open
Configures the function of the Center Loop (Shadow
Loop) when triggered:
Setting 1 - holds the gate from S.T.A.R.T.ing open and
from S.T.A.R.T.ing closed. This setting prevents opening
and closing of the gate when the Center Loop is tripped if
the gate is on either (opened or closed) limit switches.
Setting 0 - holds the gate from S.T.A.R.T.ing closed. This
setting prevent closing when on the open limit switch.
CENTER LOOP
COM
27
1 = Standard
2 = Quick close
Configures for faster closure. This selection determines
whether the close timer begins to count after vehicles have
departed the detector loops or whether the close timer will
count down while the loops are occupied. The gate can
only close when all loop detectors are not triggered.
The default setting causes the Close Timer to S.T.A.R.T.
when the Center Loop is clear. A setting of 2 causes the
Close Timer to S.T.A.R.T. when the open limit switch
trips.
HY-5A
27
0 = Disabled
1 to 25 available
Configures the function of the user 1 output relay, which is
a large relay. It has the capacity to switch both AC and DC
and can be used for high voltage and/or high current loads.
Connect devices directly to the top of the relay: COM plus
NO and NC contacts.
Additionally, there are 25 optional logic function choices,
which are described in detail in
Setting the User Relay Function
in the Installer Menu
User 1 Relay
Table 3-2. Smart DC Controller - Installer Menu Functions (Continued)
Ref.
No.
*
Installer Menu
Setting Options
(
Bold = Factory Settings
)
Tasks and Explanations
Associated
DC Controller
Connections
Display
HD 1 HOLD OPEN
CENTER LOOP HOLD
DL 1 STANDARD
DETECTOR LOGIC
RL 1 0 DISABLED
RELAY 1 LOGIC